IBM Support

PK35741: IMS V10 RUN UNDER SUPPORT FOR HPFPU V3.1

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as new function.

Error description

  • IMS V10 run under support for HPFPU V3.1.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of High Performance Fast Path      *
    *                 Utilities Version 3 Release 1                *
    *                 (FMID: H31A310).                             *
    ****************************************************************
    * PROBLEM DESCRIPTION: This APAR enables HPFPU for z/OS        *
    *                      Version 3 Release 1 to run on IMS       *
    *                      Version 10 (5635-A01).                  *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    HPFPU V3R1 are changed to support IMS Version 10.
    

Problem conclusion

Temporary fix

Comments

  • ========================
    = DOCUMENTATION CHANGE =
    ========================
    ----------------------------------------------------
    * Volume 1: Fast Path Advanced Tool (SC18-9869-00) *
    ----------------------------------------------------
    The IMS High Performance Fast Path Utilities for z/OS
    User's Guide Volume 1: Fast Path Advanced Tool (SC18-9869-00)
    should be changed as follows:
    
    About this information
     Terminology used in this book
    The following description should be added in the IMS list:
    . IMS Version 10 refers to IMS Version 10 Release 1
    
    Chapter 2. Fast Path Advanced Tool
       Job control language (JCL)
        EXEC statement
          After IMSPLEX= explanation
            DBRCGRP=
               DBRCGRP is a one- to three-character optional
               parameter is used by DBRC to identify which sharing
               group the notification belongs to.
    
        DD statement
            IMSACB DD
              After "Notes on dynamic allocation" explanation
                The DFSMDA member for IMSACB can not be used under
                IMS Version 10.
    
    ----------------------------------------------------
    * Volume 2: Fast Path Basic Tools (SC18-9870-00)   *
    ----------------------------------------------------
    The IMS High Performance Fast Path Utilities for z/OS
    User's Guide Volume 2: Fast Path Basic Tools Version 3 Release 1
    (SC18-9870-00) should be changed as follows:
    
    About this information
     Terminology used in this book
    The following description should be added in the IMS list:
    . IMS Version 10 refers to IMS Version 10 Release 1
    
    Chapter 3. Using DEDB Pointer Checker utility
      Job control language (JCL)
        FABADA1 JCL
          EXEC
            IMSPLEX=
               IMSPLEX is a one- to five-character optional
               parameter specifying which IMSplex DBRC should
               join in.
            DBRCGRP=
               DBRCGRP is a one- to three-character optional
               parameter is used by DBRC to identify which sharing
               group the notification belongs to.
            After RECON3 DD explanation
               You need to specify IMSPLEX and DBRCGRP parameters
               on EXEC statement for parallel RECON access to ensure
               all DBRC instances in a sharing group have access to
               the same RECON data sets.
    
    Chapter 13. Using the DEDB Unload utility - FABCUR1
      Job control language (JCL)
        EXEC statement
            IMSPLEX=
               IMSPLEX is a one- to five-character optional
               parameter specifying which IMSplex DBRC should
               join in.
            DBRCGRP=
               DBRCGRP is a one- to three-character optional
               parameter is used by DBRC to identify which sharing
               group the notification belongs to.
        DD statement
            After RECON3 DD explanation
               You need to specify IMSPLEX and DBRCGRP parameters
               on EXEC statement for parallel RECON access to ensure
               all DBRC instances in a sharing group have access to
               the same RECON data sets.
    
    Chapter 14. Using the DEDB Reload utility - FABCUR3
      Job control language (JCL)
        EXEC statement
            DBRCGRP=
               DBRCGRP is a one- to three-character optional
               parameter is used by DBRC to identify which sharing
               group the notification belongs to.
        DD statement
            After RECON3 DD explanation
               You need to specify IMSPLEX and DBRCGRP parameters
               on EXEC statement for parallel RECON access to ensure
               all DBRC instances in a sharing group have access to
               the same RECON data sets.
    
    Appendix O. FPB - Messages and codes
    The FABA4095E and FABC4095E messages should be added as follows:
     FABA Messages
     ---------------------------------------------------------------
     FABA4095E RECON ACCESS FAILED. DBRC LIST COMMAND IS NOT
               COMPLETED. RC=xxxxxxxx
     FABA4095E RECON ACCESS FAILED. SYSPRINT DD FOR DBRC LIST
               COMMAND IS SPECIFIED AS DUMMY
     FABA4095E RECON ACCESS FAILED. INTERNAL ERROR OCCURED
     FABA4095E RECON ACCESS FAILED. FUNC=fffffffff
               RETURN CODE=xxxxxxxx REASON CODE=xxxxxxxx
               KEYS: DBD=dbdnam DDN=ddname KEYTYPE=xx xxxxxxxxxx
    
     Explanation: An error was detected in the RECON access
     processing.
     System action: FABADA1 ends with an abend code of 4095.
     User response: Check the DBRC message preceding this message,
     follow the response in that message, and rerun the job.
     ---------------------------------------------------------------
     FABC Messages
     ---------------------------------------------------------------
     FABC4095E RECON ACCESS FAILED. DBRC LIST COMMAND IS NOT
               COMPLETED. RC=xxxxxxxx
     FABC4095E RECON ACCESS FAILED. SYSPRINT DD FOR DBRC LIST
               COMMAND IS SPECIFIED AS DUMMY
     FABC4095E RECON ACCESS FAILED. INTERNAL ERROR OCCURED
     FABC4095E RECON ACCESS FAILED. FUNC=fffffffff
               RETURN CODE=xxxxxxxx REASON CODE=xxxxxxxx
               KEYS: DBD=dbdnam DDN=ddname KEYTYPE=xx xxxxxxxxxx
    
     Explanation: An error was detected in the RECON access
     processing.
     System action: FABCUR1 or FABCUR3 ends with an abend code of
     4095.
     User response: Check the DBRC message preceding this message,
     follow the response in that message, and rerun the job.
     ---------------------------------------------------------------
    
    ----------------------------------------------------
    * Volume 3: Fast Path Online Tools (SC18-9871-00)  *
    ----------------------------------------------------
    The IMS High Performance Fast Path Utilities for z/OS
    User's Guide Volume 3: Fast Path Online Tools (SC18-9871-00)
    should be changed as follows:
    
    About this information
     Terminology used in this book
    The following description should be added in the IMS list:
    . IMS Version 10 refers to IMS Version 10 Release 1
    
    Chapter 4. Using OPC
      JCL considerations
    Chapter 10. Using OAE
    
    The following description should be added before JCL
    statements in Chapter 4 and before JCL requirements
    in Chapter 10:
    
    DBRC SCI registration exit routine
    If you are using the RECON data set, in which an
    IMSplex name and a DBRC group are set,
    you must use the DBRC SCI registration exit routine
    (DSPSCIX0) to pass the IMSplex name and DBRC group to DBRC.
    You must specify DSPSCIX0 to use parallel RECON access.
    
    The SCI registration exit routine is called by DBRC before
    registering with the SCI. The exit routine supplies the IMSplex
    name and DBRC group needed for SCI registration. For more
    information about the DBRC SCI registration exit, see the IMS
    Customization Guide.
    
    Chapter 4. Using OPC
     JCL statements
      DD statements
    Chapter 10. Using OAE
     JCL requirements
      DD statements
    
    The following description should be added as follows:
    STEPLIB DD
        The data set that contains DBRC SCI registration exit
        routine (DSPSCIX0) must be concatenated when using the RECON
        data set, in which an IMSplex name is set.
    
    
    Chapter 5. Introduction to ODE
    Chapter 11. Introduction to OER
    Chapter 14. Introduction to ODM
     Software requirements
    
    The following description should be added in the IMS Database
    Managers list:
    . IMS Version 10 Release 1 Database Manager
    (Program number: 5635-A01)
    
    Also, the program number of IMS Version 8 Release 1 and IMS
    Version 9 Release 1 should be modified as follows:
    . IMS Version 8 Release 1 Database Manager
    (Program number: 5655-C56)
    . IMS Version 9 Release 1 Database Manager
    (Program number: 5655-J38)
    
    Appendix F. Messages and codes
    The following message should be removed:
    
    FPX0108E SDEPHIER keyword is permitted only for IMS 7.1, IMS 8.1
    and IMS 9.1.
    

APAR Information

  • APAR number

    PK35741

  • Reported component name

    IMS HP FP UTILI

  • Reported component ID

    5655K9400

  • Reported release

    310

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2006-12-05

  • Closed date

    2006-12-27

  • Last modified date

    2007-01-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  •    DA5MAIN0 DA5PFSI0 DA5T1XP0 FABAARCA FABAARC0
    FABABMAP FABACKCC FABACNVT FABADA1  FABADA5  FABADA7  FABADA7A
    FABADA70 FABADBCI FABADMAC FABAFDAR FABAGDD  FABAHEXT FABAHSCA
    FABAINIT FABALINK FABASDEP FABAUMSG FABA1SBM FABA1SB0 FABBGDD
    FABCARCA FABCARC0 FABCGDD  FABCMMCL FABCMMIF FABCMPC0 FABCSREC
    FABCUR1  FABCUR1U FABC1DMA FABC1EOJ FABC1EXR FABC1EXT FABC1GCD
    FABC1INI FABC1OP1 FABC1OP2 FABC1SBM FABC1SB0 FABC1SCH FABC1UDT
    FABC3ARE FABC3END FABC3INI FABC3SBM FABC3SB0 FABC3UOW FABC5PRT
    FABC7AUD FABC7GET FABC7INI FABDARCN FABDGDD  FABUARCA FABUARCN
    FABUCPYR FABURRPD FPXAB35A FPXACLEA FPXADBT0 FPXADRVA FPXADSCA
    HFPXBRLA HFPXBRLM HFPXBRL8 HFPXBRL9 HFPXURX0 HFPY1010 HFPY1510
    HFPZCDB  HFPZICT  HFPZMCT  H31A310J UR#DICT0
    

Publications Referenced
SC18986900SC18987000SC18987100  

Fix information

  • Fixed component name

    IMS HP FP UTILI

  • Fixed component ID

    5655K9400

Applicable component levels

  • R310 PSY UK20917

       UP06/12/29 P F612

[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89D","label":"IMS HP Fast Path Utilities"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0"}]

Document Information

Modified date: