Error description
During the batch collect process, we receive an ABEND0C4 in IDLGINPT at offset x'125E'. The abend occurs because IDLGINPT is attempting to reference a DBD that has not been loaded into storage.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: IMS DATABASE CONTROL SUITE V3R2 * **************************************************************** * PROBLEM DESCRIPTION: 1.ABEND0C4 in IDLGINPT during batch * * collect process for all DBDs. * * 2.Error message 'DBD dbdname is not a * * DBD. Could be a PSB'. * **************************************************************** * RECOMMENDATION: * **************************************************************** THE ABEND0C4 IN IDLGINPT WAS CAUSED BY A REFERENCE TO A MISSING DBD POINTER IN THE PRINT ERROR MESSAGE PROC. THE DBD, A SHARED SECONDARY INDEX DATABASE, IS NOT SUPPORTED BY CONTROL SUITE. THE ATTEMPT TO PRINT THE ERROR MESSAGE CAUSED THE ABEND. THE ERROR MESSAGE - 'DBD "NAME" IS NOT A DBD. COULD BE A PSB' DID NOT ADEQUATELY EXPLAIN THE FAILURE OF THE SHARED SECONDARY INDEX DATABASE.
Problem conclusion
IDLGINPT HAS BEEN MODIFIED TO SKIP REFERENCES TO UNLOADED DBDS IN ERROR MESSAGES. THE MESSAGE IN QUESTION HAS BEEN UPDATED TO INDICATE THAT CONTROL SUITE DOES NOT SUPPORT SHARED SECONDARY INDEX DATABASES.
Temporary fix
Comments
APAR Information
APAR number
PK27059
Reported component name
IMS DB CNTL SUI
Reported component ID
5655F7600
Reported release
320
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2006-06-23
Closed date
2006-06-28
Last modified date
2006-07-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK15853
Modules/Macros
IDLC0001 IDLGINPT IDLICEC3 IDLRREXR IDLRREXW IDLRREX2
| SC18763004 |
Fix information
Fixed component name
IMS DB CNTL SUI
Fixed component ID
5655F7600
Applicable component levels
R320 PSY UK15853
UP06/06/30 P F606
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX88W","label":"IMS Database Control Suite"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2.0"}]
Document Information
Modified date:
22 October 2020