A fix is available
APAR status
Closed as program error.
Error description
After IMS terminated abnormally, IMS needs to perform a Log Recovery process against the latest OLDS. IMS needs to add two log records (06/48), then close the OLDS properly. This occurs either in the FDBR region or in the followed ERE processing. During this procesing, IMS received a D37 error on the secondary OLDS, IEC031I D37-04,IFG0554P,imsctl,,DFSOLSxx... IMS successfully added the two records into primary OLDS, but failed to add the records into secondary OLDS. As a response to the D37 error, IMS incorrectly marked the primary OLDS in error and generated an archive JCL against the secondary OLDS. Since we missed two log records in the secondary OLDS, this also caused a problem to the log sequence number (LSN) in SLDS. If single OLDS logging is being used, then after the D37, the /ERE fails with ABENDU005-1C
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * All IMS V15 users with PI75575/UI54239 applied. * **************************************************************** * PROBLEM DESCRIPTION: * * While closing the log as part of FDBR processing, XRF * * takeover, or emergency restart, IMS can either abend or * * record incorrect information about an OLDS in DBRC. * **************************************************************** * RECOMMENDATION: * * INSTALL CORRECTIVE SERVICE FOR APAR/PTF * **************************************************************** While closing the log as part of FDBR processing, XRF takeover, or emergency restart processing, the IMS Logger tries to write a type06 and type48 record to the OLDS being closed. An incorrect argument to the BSAM POINT macro was causing this WRITE to be attempted past the end of the OLDS, causing the WRITE to get an ABENDD37. What happens after the ABENDD37 depends on whether single or dual OLDS logging is in place. With single OLDS logging, ABENDU0005 RSN0000001C occurs after msgDFS0738X and msgDFS0738I are produced. If dual logging is being used, the ABENDD37 occurs on the secondary OLDS, but msgDFS0738I is produced, indicating a CLOSE error on the _primary_ OLDS, and restart appears to complete successfully. However, since it was incorrectly determined that the error occured on the primary, the secondary OLDS is the one used by archive for the PRILOG record in DBRC. But since it's the secondary OLDS that got the error, the LSN range for that log is incorrect as it doesn't have the last 2 log records, which are the ones whose WRITE got the ABENDD37. Also, if the ABENDD37 happens during FDBR processing, an ensuing emergency restart of the failed IMS can take ABEND0C9 in DFSFDLY1 because of RLWECNT being 0. The root cause of the ABEND0C9 is the ABENDD37, which is addrsesed by this APAR.
Problem conclusion
So this APAR addresses 3 problems in this area. 1. The cause of the ABENDD37 is a bad POINT argument in code added by PI75575 to address an 'out of sync' condition when zHyperWrite is used to where an update could make it to the remote copy of the data set, but not on the primary copy in a small timing window. Upon restarting, IMS must re-write the last 255 blocks of the OLDS right back in place so that they can be replicated to the new secondary, which was the old primary that might not have gotten the WRITEs initially. Note that the terms 'primary' and 'secondary' in this context refer to the same data set in a replication environment, not primary and secondary OLDS, which are different data sets. For the ABENDD37 to occur, IMS must be trying to write past the end of the OLDS. IMS tries to write past the end of the data set if the number of blocks read by restart times 2, minus 255, exceeds the capacity of the OLDS. Note that restart only reads a subset of the blocks on the OLDS. 2. Upon getting the ABENDD37 on the secondary OLDS, it appeared that a CLOSE error happened on the primary OLDS. A CLOSE error was not actually happening, but it appeared that it was happening because a flag was on indicating that the abend exit was driven after the CLOSE. This flag being on was residual and was actually turned on by the WRITE to the secondary that got the ABENDD37, but was not checked after that WRITE, so the next operation for an OLDS (in this case closing the primary OLDS), made it appear that the CLOSE operation resulted in the abend exit being driven. The WRITE to the secondary that got the ABENDD37 still resulted in a good POST code from BSAM, but this APAR adds code to now check whether or not the abend exit was driven for the WRITE. 3. While re-creating the reported problem, it was also discovered that addressing the 'out of sync' condition for zHyperWrite processing was only happening on the secondary OLDS and not the primary OLDS in a dual OLDS logging environment. This APAR now causes both OLDS go through the code that addresses the 'out of sync' condition. Note that the log recovery utility (DFSULTR0) also has code to address the 'out of sync' condition for zHyperWrite (as it also closes the log), but does not have these errors. Also note that during restart, it's possible that IMS might not be able to determine whether or not the abending IMS was using zHyperWrite for the OLDS, so an IMS does not have to have ZHYPERWRITE=(OLDS=YES) specified to be exposed to this.
Temporary fix
********* * HIPER * *********
Comments
APAR Information
APAR number
PI97598
Reported component name
IMS V15
Reported component ID
5635A0600
Reported release
500
Status
CLOSED PER
PE
YesPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-05-04
Closed date
2018-06-15
Last modified date
2018-07-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI56597
Modules/Macros
DFSFDLU0 DFSFDLY0
Fix information
Fixed component name
IMS V15
Fixed component ID
5635A0600
Applicable component levels
R500 PSY UI56597
UP18/06/20 P F806