Error description

  • Repository Control Block (FPQINFO) is returned from the FPQ
    server to the FPQ client when the FPQ client calls FPQSRV
    FUNC=CONTROL TYPE=QUERY.
    The FPQ server constructs the FPQINFO block, but there is
    possibility that the FPQ server may set wrong values. As the
    result the FPQ client refers the wrong values and causes
    problem with ABEND0C4.
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of IBM IMS Tools Base for z/OS     *
    *                 Version 1 Release 6 (FMID: HAHN160).         *
    ****************************************************************
    * PROBLEM DESCRIPTION: ABEND S0C4 ( ABEND0C4 ) occurs at       *
    *                      module BSNSDSD2 offset x'BE8' when the  *
    *                      Sensor data services is used.           *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    The internal control block is constructed by the FPQ server when
    the client requests the repository I/O request.
    However, there is possibility that the FPQ server module may set
    wrong values to internal control block.
    As the result, the client modules refers its values and might
    unexpected results.
    
    The cause of this problem is that the storage of the internal
    control block obtained by FPQ server module does not initialize
    with low-values.
    If the storage has dirty values (not low-values) when it is
    obtained, FPQ server will set the wrong values to internal
    control blocks.
    

Problem conclusion

  • The IMS Tools KB has been modified to clear the obtained storage
    with low-values.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI94966

  • Reported component name

    TOOLS BASE

  • Reported component ID

    5655V9300

  • Reported release

    160

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-03-09

  • Closed date

    2018-07-04

  • Last modified date

    2018-08-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI57032

Modules/Macros

  •    FPQSIORQ
    

Fix information

  • Fixed component name

    TOOLS BASE

  • Fixed component ID

    5655V9300

Applicable component levels

  • R160 PSY UI57032

       UP18/07/10 P F807

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCJN3E","label":"IBM Tools Base"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"160"}]

Document Information

Modified date:
19 October 2020