Error description
Step to reproduce : Create a new Type tree. Add a new item Set it to number , binary , packet Change the Length to 8 A pop up error appear the .log file show : !ENTRY org.eclipse.ui 4 0 2009-06-02 08:11:19.107 !MESSAGE java.lang.Integer incompatible with java.lang.String !STACK 0 java.lang.ClassCastException: java.lang.Integer incompatible with java.lang.String at com.ibm.websphere.dtx.ui.te.properties.LengthPackComboBoxPropert yDescriptor.setPropertyValue(Unknown Source) at com.ibm.websphere.dtx.ui.mercdev.WTXPropertySource.setPropertyVa lue(Unknown Source) at com.ibm.websphere.dtx.ui.mercdev.WTXPropertySheetEntry.valueChan ged(Unknown Source) at com.ibm.websphere.dtx.ui.mercdev.WTXPropertySheetEntry.setValue( Unknown Source) at com.ibm.websphere.dtx.ui.mercdev.WTXPropertySheetEntry.applyEdit orValue(Unknown Source) at com.ibm.websphere.dtx.ui.mercdev.controls.WTXPropertySheetViewer .applyEditorValue(Unknown Source) at com.ibm.websphere.dtx.ui.mercdev.controls.WTXPropertySheetViewer .handleSelect(Unknown Source) at com.ibm.websphere.dtx.ui.mercdev.controls.WTXPropertySheetViewer .access$7(Unknown Source) at com.ibm.websphere.dtx.ui.mercdev.controls.WTXPropertySheetViewer $5.mouseDown(Unknown Source) at org.eclipse.swt.widgets.TypedListener.handleEvent(TypedListener. java:133) at org.eclipse.swt.widgets.EventTable.sendEvent(EventTable.java:66) at org.eclipse.swt.widgets.Widget.sendEvent(Widget.java:928) at org.eclipse.swt.widgets.Display.runDeferredEvents(Display.java:3 348) at org.eclipse.swt.widgets.Display.readAndDispatch(Display.java:296 8) at org.eclipse.ui.internal.Workbench.runEventLoop(Workbench.java:19 30) at org.eclipse.ui.internal.Workbench.runUI(Workbench.java:1894) at org.eclipse.ui.internal.Workbench.createAndRunWorkbench(Workbenc h.java:422) at org.eclipse.ui.PlatformUI.createAndRunWorkbench(PlatformUI.java: 149) at org.eclipse.ui.internal.ide.IDEApplication.run(IDEApplication.ja va:95) at org.eclipse.core.internal.runtime.PlatformActivator$1.run(Platfo rmActivator.java:78) at org.eclipse.core.runtime.internal.adaptor.EclipseAppLauncher.run Application(EclipseAppLauncher.java:92) at org.eclipse.core.runtime.internal.adaptor.EclipseAppLauncher.sta rt(EclipseAppLauncher.java:68) at org.eclipse.core.runtime.adaptor.EclipseStarter.run(EclipseStart er.java:400) at org.eclipse.core.runtime.adaptor.EclipseStarter.run(EclipseStart er.java:177) at sun.reflect.NativeMethodAccessorImpl.invoke0(Native Method) at sun.reflect.NativeMethodAccessorImpl.invoke(NativeMethodAccessor Impl.java:64) at sun.reflect.DelegatingMethodAccessorImpl.invoke(DelegatingMethod AccessorImpl.java:43) at java.lang.reflect.Method.invoke(Method.java:615) at org.eclipse.core.launcher.Main.invokeFramework(Main.java:336) at org.eclipse.core.launcher.Main.basicRun(Main.java:280) at org.eclipse.core.launcher.Main.run(Main.java:977) at org.eclipse.core.launcher.Main.main(Main.java:952) !ENTRY org.eclipse.ui 4 4 2009-06-02 08:11:19.420 !MESSAGE Unhandled event loop exception
Local fix
WTX00030919
Problem summary
Problem Description: Design Studio was throwing an exception when setting up the Length field for a Packed Binary number item in a type tree. The ClassCast Exception has been corrected where Integer value was incorrectly being casted to String resulting in pop-up message showing the failure. The issue has been resolved and Design Studio now allows the length to be set for Packed numbers. Users Affected: 8.2.0.4 and older 8.2.x Design Studio users Platforms Affected: Windows
Problem conclusion
Fixed a problem with Design Studio where it throws an exception and fails to set the length for a Packed Binary number item in a type tree. Delivered in: 8.2.0.5, 8.3.0.0
Temporary fix
Comments
APAR Information
APAR number
PK87843
Reported component name
WEBSPHERE DESIG
Reported component ID
5724M4008
Reported release
820
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2009-06-03
Closed date
2009-06-26
Last modified date
2009-06-26
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WEBSPHERE DESIG
Fixed component ID
5724M4008
Applicable component levels
R820 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSD8","label":"IBM Transformation Extender"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.2","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information
Modified date:
26 June 2009