IBM Support

PK84992: KO2O1348E NEAR-TERM HISTORY DATA COLLECTOR - READA/READS FAILED.REASON CODE 00E60826 (CHECKRET).

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • KO2O1348E NEAR-TERM HISTORY DATA COLLECTOR - READA/READS FAILED.
    REASON CODE 00E60826 (CHECKRET).
    
    Near-Term History failed to be started and received the message
    of KO2O1348E NEAR-TERM HISTORY DATA COLLECTOR - READA/READS
    FAILED.  REASON CODE 00E60826 (CHECKRET).
    
    we should say it's mandatory for ACCTG Class 1: Y.
    
    e.g.
    D2#6 job:
    *
    STATISTICS(YES)
    SCAN(NO)
    SORT(NO)
    *
    FYI.
    KD261MC2    Specify OMEGAMON XE for DB2 PE Subsystem
    RTE:  SYSG ----
    Option ===>
                          DB2 Subsystem ID: D71D
     Select one or more options to configure OMEGAMON XE for DB2
    Performance
     Expert on z/OS. To update the entire configuration, type ALL.
    To update
     specific values, select the corresponding options from the
    list.
    
    Last  selected
    
    Date  Time
      1  DB2 subsystem information                    (mandatory)
      2  Object/Volume Analysis configuration         (mandatory)
      3  Application Trace Facility configuration
      4  Automatic Exception Processing configuration
      5  Near Term Historical Collector configuration (mandatory)
      6  Snapshot History configuration
      7  Performance Warehouse configuration
      8  DB2 EXPLAIN configuration
      9  SQL Performance Analyzer configuration
      Note: Options highlighted as mandatory require configuration.
     F1=Help  F3=Back
    
    KD261PB  OMEGAMON XE for DB2 PE Near Term History configuration
    SSID:  D71D
    Command ===>
     Specify which data should be collected:
      Scan summary      ==> N     Sort summary      ==> N
      Dynamic SQL       ==> N     Lock contention   ==> N
      Lock suspension   ==> N     Statistics        ==> Y
      Negative SQL      ==> N
      Acctg class  ==> 1: N   2: N   3: N   7: N   8: N   10: N
    

Local fix

  • It's mandatory for ACCTG Class 1: Y.  Set ACCTG(1) via ICAT
    process.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component                           *
    *                 - OMEGAMON Server                            *
    ****************************************************************
    * PROBLEM DESCRIPTION: Historical collector startup fails when *
    *                      only STATISTICS data is requested.      *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF                               *
    ****************************************************************
    PROBLEM SUMMARY:
    When no accounting or performance data is requested during
    historical collector configuration, no -START TRACE commands
    are issued on startup, thus no valid OPx buffer is allocated.
    
    PROBLEM CONCLUSION:
    Startup logic is changed to establish a valid OPx buffer
    for historical collector use.
    
    KEYWORDS: KO2O1348E NEAR-TERM-HISTORY READA-READS-FAILED
    

Problem conclusion

  • Startup logic is changed to establish a valid OPx buffer
    for historical collector use.
    
    KEYWORDS: KO2O1348E NEAR-TERM-HISTORY READA-READS-FAILED
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK84992

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    410

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-04-20

  • Closed date

    2009-07-25

  • Last modified date

    2009-09-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK48696 PM31179

Modules/Macros

  • KO2CNAGB KO2ICOLA KO2ICOLS KO2ICOL2 KO2ONAFB
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R410 PSY UK48696

       UP09/08/05 P F908

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
02 September 2009