IBM Support

PK79673: FPA RELOAD ABENDU3210 AFTER PK72738 / UK41381 HAS BEEN INSTALLED

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • FPA RELOAD abends with U3210 after PK72738/UK41381 has been
    applied.
    This problem occurs if all following conditions are satisfied:
      - OCACHE=YES is specified.
      - 121 or more IOVF CIs are defined, and 101 or more of them
        are used.
      - A UOW has 59 or fewer CIs.
    
    Keywords: MSGHFPK3210E HFPK3210E
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of High Performance Fast Path      *
    *                 Utilities Fast Path Advanced Tool Version 3  *
    *                 Release 2 (FMID: H31A320).                   *
    ****************************************************************
    * PROBLEM DESCRIPTION: FPA RELOAD and CHANGE abend with U3210  *
    *                      after PK72738/UK41381 has been applied. *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    This problem occurs if all following conditions are satisfied:
      - OCACHE=YES is specified.
      - 121 or more IOVF CIs are defined, and 101 or more of them
        are used.
      - A UOW has 19 or fewer CIs.
    
    The abend occured because the data space was formatted
    incorrectly. It is a code error in APAR PK72738.
    

Problem conclusion

  • The module HFPVIIC0 has been modified to format the data space
    correctly when a UOW has 19 or fewer CIs.
    320Y
    HFPVIIC0
    

Temporary fix

  • *********
    * HIPER *
    *********
    

Comments

APAR Information

  • APAR number

    PK79673

  • Reported component name

    IMS HP FP UTILI

  • Reported component ID

    5655K9400

  • Reported release

    320

  • Status

    CLOSED PER

  • PE

    YesPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2009-01-29

  • Closed date

    2009-02-09

  • Last modified date

    2009-03-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK43897

Modules/Macros

  •    HFPVIIC0
    

Fix information

  • Fixed component name

    IMS HP FP UTILI

  • Fixed component ID

    5655K9400

Applicable component levels

  • R320 PSY UK43897

       UP09/02/11 P F902 «

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89D","label":"IMS HP Fast Path Utilities"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2.0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
03 March 2009