APAR status
Closed as program error.
Error description
FPA RELOAD abends with U3210 after PK72738/UK41381 has been applied. This problem occurs if all following conditions are satisfied: - OCACHE=YES is specified. - 121 or more IOVF CIs are defined, and 101 or more of them are used. - A UOW has 59 or fewer CIs. Keywords: MSGHFPK3210E HFPK3210E
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of High Performance Fast Path * * Utilities Fast Path Advanced Tool Version 3 * * Release 2 (FMID: H31A320). * **************************************************************** * PROBLEM DESCRIPTION: FPA RELOAD and CHANGE abend with U3210 * * after PK72738/UK41381 has been applied. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** This problem occurs if all following conditions are satisfied: - OCACHE=YES is specified. - 121 or more IOVF CIs are defined, and 101 or more of them are used. - A UOW has 19 or fewer CIs. The abend occured because the data space was formatted incorrectly. It is a code error in APAR PK72738.
Problem conclusion
The module HFPVIIC0 has been modified to format the data space correctly when a UOW has 19 or fewer CIs. 320Y HFPVIIC0
Temporary fix
********* * HIPER * *********
Comments
APAR Information
APAR number
PK79673
Reported component name
IMS HP FP UTILI
Reported component ID
5655K9400
Reported release
320
Status
CLOSED PER
PE
YesPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2009-01-29
Closed date
2009-02-09
Last modified date
2009-03-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK43897
Modules/Macros
HFPVIIC0
Fix information
Fixed component name
IMS HP FP UTILI
Fixed component ID
5655K9400
Applicable component levels
R320 PSY UK43897
UP09/02/11 P F902 «