A fix is available
APAR status
Closed as program error.
Error description
ABEND0C4 BPLMODEL CAUSED BY INCORRECT PROCESSING OF SPLIT GTF RECORDS. This APAR also fixes MSGBPL530E INVALID SUBPOOL SPECIFIED.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All IMS Buffer Pool Analyzer users. * **************************************************************** * PROBLEM DESCRIPTION: ABEND0C4 in BPLMODEL * **************************************************************** * RECOMMENDATION: * **************************************************************** ABEND0C4 in BPLMODEL caused by incorrect processing of split GTF records. Message BPL530E issued incorrectly.
Problem conclusion
Correct the split GTF Trace record header length used to reconstruct split records. Correct DBD Subpool Validation processing.
Temporary fix
Comments
×**** PE09/02/12 FIX IN ERROR. SEE APAR PK80549 FOR DESCRIPTION
APAR Information
APAR number
PK79313
Reported component name
IMS BUFFER POOL
Reported component ID
5697H7700
Reported release
120
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2009-01-23
Closed date
2009-02-06
Last modified date
2009-03-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK43838 PK80549
Modules/Macros
BPLBLAN1 BPLMAIN BPLMODEL
Fix information
Fixed component name
IMS BUFFER POOL
Fixed component ID
5697H7700
Applicable component levels
R120 PSY UK43838
UP09/02/07 P F902
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.