Troubleshooting
Problem
The battery recondition check on the IBM Cloud Pak System W3500 system gives an error message as follows:
SQL statement is invalid due to incorrect schema
SQL statement is invalid due to incorrect schema
Description
The battery recondition check is for W3550 system. But, the same job tries to check for flash system on W3500 where it is not available. When it is unable to find any value, it returns a null value. This null value when passed to process the BatteryRecondition method fails the job.
Symptom
The query_storage job state fails.
Document Location
Worldwide
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSFQSV","label":"IBM Cloud Pak System Software"},"Component":"","Platform":[{"code":"PF002","label":"AIX"},{"code":"PF016","label":"Linux"}],"Version":"2.3.1.1","Edition":"All editions","Line of Business":{"code":"LOB77","label":"Automation Platform"}}]