IBM Support

Enhancement of battery recondition code to bypass IBM Cloud Pak System W3500 system check

Troubleshooting


Problem

The battery recondition check on the IBM Cloud Pak System W3500 system gives an error message as follows:
SQL statement is invalid due to incorrect schema
Description
The battery recondition check is for W3550 system. But, the same job tries to check for flash system on W3500 where it is not available. When it is unable to find any value, it returns a null value. This null value when passed to process the BatteryRecondition method fails the job.

Symptom

The query_storage job state fails. 

Document Location

Worldwide

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSFQSV","label":"IBM Cloud Pak System Software"},"Component":"","Platform":[{"code":"PF002","label":"AIX"},{"code":"PF016","label":"Linux"}],"Version":"2.3.1.1","Edition":"All editions","Line of Business":{"code":"LOB77","label":"Automation Platform"}}]

Log InLog in to view more of this document

This document has the abstract of a technical article that is available to authorized users once you have logged on. Please use Log in button above to access the full document. After log in, if you do not have the right authorization for this document, there will be instructions on what to do next.

Document Information

Modified date:
06 May 2020

UID

ibm13220599