Error description

  • If the EYUSTARTLIBDSN.TABULAR view is selected to retrieve
    library dataset names, and your DFHRPL DD concatenation has 93
    or more datasets, a storage violation will occur for the long
    running task CONL (or CONA if you have MASALTLRTCNT specified in
    your EYUPARM parameters.)
    The EYUSTARTLIBDSN view causes an EXEC CICS INQUIRE
    LIBRARY(DFHRPL) to be issued under the covers in the MAS.
    Because CONL and CONA are long running tasks, and overlays are
    normally detected when storage is FREEMAIN'd, you may not
    receive the SM0102 dump immediately.  It may not come out until
    you attempt to shut down your CICS region (MAS), or you perform
    other queries through the WUI which cause the storage to be
    FREEMAIN'd.
    If you happen to be running with trace turned on and the CICS
    Storage Violation Trap enabled through SIT parm CHKSTSK=YES or
    by turning it on using transaction
       CSFE DEBUG,CHKSTSK=CURRENT
    while the region is running, the violation will be detected when
    it occurs, rather than at FREEMAIN time, and an SM0103 dump will
    be produced.
    .
    Additional Keywords:  DFHSM0102 DFHSM0103 0F0C code X'0F0C'
    DFHSMAR 00000F0C CPSM KIXREVCEW
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICSPlex SM V3R2M0 Users                 *
    ****************************************************************
    * PROBLEM DESCRIPTION: Storage overlays will occur in a MAS    *
    *                      when the LIBDSN resource table is       *
    *                      requested through the API or WUI, if    *
    *                      more than 92 dataset names are          *
    *                      returned.  This can result in           *
    *                      unpredictable and invalid processing    *
    *                      and CICS storage violations.  Note that *
    *                      the area overlaid is normally allocated *
    *                      for the life of the MAS, so the CICS    *
    *                      storage violations may not occur until  *
    *                      the MAS is terminated.                  *
    ****************************************************************
    * RECOMMENDATION: After applying the PTF that resolves this    *
    *                 APAR, all MASes must be restarted.  Note     *
    *                 that the restarts do not need to occur at    *
    *                 the same time.                               *
    ****************************************************************
    The first time a LIBDSN request is processed under the CONL or a
    CONA task in a MAS, a buffer large enough to handle 255 datasets
    (the CICS maximum for LIBDS) is allocated for the task.  On
    subsequent requests for the same task, the area is to be reused.
    Method EYU0NCLD (NCLD), which moves the data into the buffer,
    invalidly uses a different buffer which is 4K in length.  As a
    result, if the output moved into the buffer exceeds 4K (header
    information and more than 92 datasets), the storage following
    the 4K buffer will be overlaid.
    

Problem conclusion

  • NCLD has been updated to use the correct buffer when processing
    the LIBDSN dataset list.
    

Temporary fix

  • FIX AVAILABLE BY PTF ONLY
    

Comments

APAR Information

  • APAR number

    PK76729

  • Reported component name

    CICSTS V3 Z/OS

  • Reported component ID

    5655M1500

  • Reported release

    50M

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2008-12-02

  • Closed date

    2008-12-30

  • Last modified date

    2009-01-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK42828

Modules/Macros

  •    EYU0NCLD
    

Fix information

  • Fixed component name

    CICSTS V3 Z/OS

  • Fixed component ID

    5655M1500

Applicable component levels

  • R50M PSY UK42828

       UP09/01/01 P F812

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
02 January 2009