A fix is available
APAR status
Closed as program error.
Error description
Following ABEND0C4 in FPEVDB2I+48CE for instance, Omegamon will try to recover the DB2I functionality -- and this can lead to subsequent ABENDs. This APAR will provide first relief by no longer trying to recover the DB2I functionality, but instead shuts down the instance gracefully. This will *NOT* solve the reported 0C4 in FPEVDB2I but will avoid the several follow-on abends caused by the attempted recovery. The long-term solution remains PK73913 which will be delivered later.
Local fix
Wait at least 10 seconds before killing a VTAM session that is hanging while waiting for data.
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component: * * - PE Server subtask * * - Classic Interface * **************************************************************** * PROBLEM DESCRIPTION: Abend S0C4 occurs in module FPEVDB2I of * * the PE Server subtask. Consecutive * * abends in depending tasks occur. The * * processing of the corresponding dumps * * causes peaks in CPU consumption. * * * **************************************************************** * RECOMMENDATION: Apply this PTF * **************************************************************** PROBLEM SUMMARY: Abend S0C4 occurs in module FPEVDB2I of the PE Server subtask. Consecutive abends in depending tasks occur. The processing of the corresponding dumps causes peaks in CPU consumption. PROBLEM CONCLUSION: When an ABEND (S0C4) occurs in module FPEVDB2I of a monitoring PE Server subtask, the abend handler is invoked and writes the symptoms (PSW, Registers) to the OMEGAMON job log without requesting further dump output. Control is returned to module FPEVDB2I to free resources. The monitoring PE Server subtask stops and will be started automatically to continue monitoring of the DB2 Subsystem.
Problem conclusion
When an ABEND (S0C4) occurs in module FPEVDB2I of a monitoring PE Server subtask, the abend handler is invoked and writes the symptoms (PSW, Registers) to the OMEGAMON job log without requesting further dump output. Control is returned to module FPEVDB2I to free resources. The monitoring PE Server subtask stops and will be started automatically to continue monitoring of the DB2 Subsystem. KEYWORDS : ABEND S0C4 FPEVDB2I
Temporary fix
Comments
APAR Information
APAR number
PK76500
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
410
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2008-11-27
Closed date
2008-12-03
Last modified date
2009-04-16
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK42051
Modules/Macros
DGOVABAN DGOVHMM1 FPE@DB2I FPEVDB2I FPEVM000
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R410 PSY UK42051
UP08/12/05 P F812
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
16 April 2009