A fix is available
APAR status
Closed as program error.
Error description
ABEND878-10 during OMPE startup. Virtually all the storage below the line for SUBPOOL 255 (SP255) LSQA is filled with SCB control blocks created on behalf of an ESTAEX being issued repeated by DGOVHMTC (at PK69740 level) -- more than 137,000 of them. From SYSTRACE this can be seen: SVCR 78 078D0000 985AFED4 ... PC ... 8 185B144D 0030F Estaex PR ... 0 185B144D 01493522 SVC 78 078D2000 985B0736 ... Freemain SVCR 78 078D2000 985B0736 ... SVC 78 078D0000 985AFED4 ... Getmain SVCR 78 078D0000 985AFED4 ... PC ... 8 185B144D 0030F Estaex PC ... 0 01493226 0030B Storage Obtain SSRV 132 00000002 ... Storage Obtain 02530004 PR ... 0 01493226 014CFB9E PR ... 0 185B144D 01493522 PC ... 8 185B1465 0030F Estaex PR ... 0 185B1465 01493522 SVC 78 078D2000 985B049A ... Freemain SVC 78 078D0000 985AFED4 ... Getmain ... with the address of DGOVHMTC being 185AFE10. Other ABENDs such as ABENDC78 and ABENDD23 rc05101440 can be seen. VSMDATA reports "** User Region Top has hit bottom of LSQA".
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component: * * - PE Server subtask * **************************************************************** * PROBLEM DESCRIPTION: Omegamon has falldown with ABEND C78 * * RC04 and at restart it received ABEND * * 878 RC10 and it was no longer able to * * restart. * **************************************************************** * RECOMMENDATION: Apply this PTF * **************************************************************** PROBLEM SUMMARY: Almost all memory of private region allocated to LSQA SP 255 and filled with SCB control blosks generated by macro ESTAEX. Next request to allocate SCB control block causes abend 878-10. PROBLEM CONCLUSION: Code changed to ensure ESTAEX removed before exit from function call.
Problem conclusion
Code changed to ensure ESTAEX removed before exit from function call. KEYWORDS : LSQA ABEND878
Temporary fix
Comments
APAR Information
APAR number
PK76202
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
410
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2008-11-21
Closed date
2008-12-16
Last modified date
2009-04-22
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK42518
Modules/Macros
DGOVHMTC DGOVMSTR
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R410 PSY UK42518
UP08/12/18 P F812
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date: