A fix is available
APAR status
Closed as program error.
Error description
After maintenance customer gets garbage on the ZSUMM panel of classic when using 3 character subsystem. 3 Char ssid 3char This is example of bad screen: ________________ ZSUMM VTM O2 V410./C DSN S 08/12/08 10:05:47 > Help PF1 Back PF3 Zoom PF11 > S. ============================================================== > SUMMARY OF DB2 ACTIVITY DSYS + ....................... = 00.0% .................. = .0.... + .................. = .0.... .................. = .0.... + ................... = + ....................... = 00.0% .................. = .0.... + .................. = .0.... .................. = .0.... + ................... = + ....................... = 00.0% .................. = .0.... + .................. = .0.... .................. = .0.... + ................... = + ....................... = 00.0% .................. = .0.... Additional symptoms: > BUFFER MANAGER INFORMATION BMGR + >> KO2O1230E CONTROL BLOCK VALIDATION ERROR (OBUFBMGR) << ----------------------------------------------------------- While on 3 character DB2 SSID custome redirects to another SSID(4 character) using option Z and they get to panel ZELOG and zoom to the new SSID and get log on error message= VTAM classic log on error KO2O0905E ----------------------------------------------------------- When brought up DB2 Collector on our 3 Char SSID this message showed up: KO2O1000W DB2 ACCOUNTING CLASS ONE TRACE STATUS IS INACTIVE, ALL FIELDS CONTAINING N/A ARE UNAVAILABLE (OTHJTHDA) ----------------------------------------------------------- Signed onto the Omegamon Classic (3270)- executing SUMMARY command 'S' from the main menu get garbage then hit PF3 to return to the main menu I get a CLOCK/X-SYSTEM on my screen and the collector task goes into a hard loop and has to cancelled. ------------------------------------------------------------- Not loggin on to the CLASSIC interface (3270) but bring up the XE agent (D5), the Collector (O2) takes a S0C4 as soon as the D5 agent attempts a connection. -----------------------------------------------------------
Local fix
Please apply PTF when available.
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component: * * - PE Server * * - Classic Interface * **************************************************************** * PROBLEM DESCRIPTION: When the OMEGAMON Server is configured * * to monitor a DB2 Subsystem with a three * * character DB2 subsystem name and the * * Classic Interface (VTAM) is used to * * display performance data, errors with * * the following symptoms show up. * * When option 'S' is selected from the * * VTAM main menu panel ZMENU to display * * summary data, garbage data are * * displayed in VTAM panel ZSUMM. * * When option 'R.A' is selected from the * * VTAM main menu ZMENU to display Buffer * * Manager Information, message KO2O1230E * * is displayed. * **************************************************************** * RECOMMENDATION: Apply this PTF * **************************************************************** PROBLEM SUMMARY: When the OMEGAMON Server is configured to monitor a DB2 subsystem with a three character DB2 subsystem name and the Classic Interface (VTAM) is used to display summary data for the DB2 Subsystem with the three character subsystem name, garbage data are displayed in VTAM panel ZSUMM. When option 'R.A' is selected from the VTAM main menu to display Buffer Manager Information, message KO2O1230E is displayed. PROBLEM CONCLUSION: During initialization of the OMEGAMON Server subtask PESERVER not all parameter for a monitored DB2 Subsystem with a three character subsystem name were set. The missing parameters prevented the retrieval of certain performance data or resulted in the retrieval of wrong data. The error has been corrected.
Problem conclusion
During initialization of the OMEGAMON Server subtask PESERVER not all parameter for a monitored DB2 Subsystem with a three character subsystem name were set. The missing parameters prevented the retrieval of certain performance data or resulted in the retrieval of wrong data. The error has been corrected. KEYWORDS : VTAM CLASSIC INTERFACE ZSUMM 3 CHAR DB2 SUBSYSTEM NAME KO2O1230E
Temporary fix
Comments
APAR Information
APAR number
PK71091
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
410
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2008-08-25
Closed date
2008-09-16
Last modified date
2017-02-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK39913
Modules/Macros
DGOVMSTR DGOVPP1 DGOVRTG1 FPEVM000
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R410 PSY UK39913
UP08/09/17 P F809
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"410","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]