A fix is available
APAR status
Closed as program error.
Error description
Under IMS V10 a BMP gets an Abend0C4 on a AIBTDLI call with RSA. The problem is a one-byte overlay of the field following immediatly the RSA field, so it looks like IMS returns with 9 bytes instead of an 8-byte RSA ... .
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: ALL V10 users of GSAM. * **************************************************************** * PROBLEM DESCRIPTION: ABENDS0C4 occurs during a AIBTDLI call * * to a GSAM data base using an RSA and * * APAR PK46917/UK27322 applied. * **************************************************************** * RECOMMENDATION: INSTALL CORRECTIVE SERVICE FOR APAR/PTF * **************************************************************** ABEND0C4 occurs during a GN call, Get Next call, of a AIBTDLI call. The error occurs because code added after label MOVD0850 in APAR PK46917 moved the GBZFLAG into the byte after the User RSA Area. The User RSA Area, GBRRAPTR, is an 8 byte field that is returned to the user in the keyfeedback area. Since the GBZFLAG was stored into the next byte after the user RSA area, the value in GBBQCB was overlayed.
Problem conclusion
AIDS: RIDS/DBS RIDS/INTRF DBS INTRF GEN: KEYWORDS: *** END IMS KEYWORDS *** ************ * DFSZD210 * ************ Code added by APAR PK46917 that stored GBZFLAG into one byte after GBRRAPTR was removed from module DFSZD210 after label MOVD0850.
Temporary fix
********* * HIPER * *********
Comments
APAR Information
APAR number
PK70673
Reported component name
IMS V10
Reported component ID
5635A0100
Reported release
010
Status
CLOSED PER
PE
NoPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2008-08-18
Closed date
2008-09-11
Last modified date
2009-02-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK39806
Modules/Macros
DFSZD210
Fix information
Fixed component name
IMS V10
Fixed component ID
5635A0100
Applicable component levels
R010 PSY UK39806
UP08/09/18 P F809
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.1","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCVRBJ","label":"System Services"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.1","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
02 February 2009