IBM Support

PK68317: ABEND0C4 IN ISPF ISPDTD WHEN EXITING (PF3) QCF PANEL IQCP94C

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • ABENDS0C4 in ISPF ISPDTD x'1558' when exiting with PF3, QCF
    panel IQCP94C.
    Input panel series which produces abend is:
      IQCP00   Enter     QCF Main Menu option 2  PK58015
      IQCP91S1 Enter     Query for shared queues  ALL filter
      IQCP94C  F3=End    Messages Destination (summary)
      IQCP91S1 Enter     Query for shared queues  ALL filter
      IQCP94C  F3=End    Messages Destination (summary)
      IQCP91S1 Enter     Query for shared queues  ALL filter
      IQCP94C  F3=End    Messages Destination (summary)
    
    Additional issue this may address:
    IQC7003E - RC=0010 QCF CRITICAL ERROR IN MODULE IQCZRSP0
    SRCHZCIB   RC=00000000,RSN=NOTFCLNT   or   RSN=NOTOKENC
    When this error message shows in the server joblog and there
    are large queues with many messages, use of the waittime
    parm (that is added by this APAR) will alleviate the
    error message by increasing the wait time for the TSO client.
    This parm is specified in the server customization member as:
      IMSPLEX=PLEX1
      AUTH=N
      WAITTIME=120  <-- here (see responder page for more info on
                                                               this)
    Additional issues fixed:
    1) Online query getting: IQC4065T QCF/IMS conflict.
    This happens due to a timeout of the QUERY request and
    when there are a large amount of messages on the LMSGQ.
    
    As part of this additional issue fixed we are adding a
    timeout parameter so customers can set their own wait time
    timeout.
    
    2) ABEND30A - 1C running the IQCFCKPT step
       Keywords: ABENDS30A S30A 30A-1C REASON=0000001C
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of QCF3.1                          *
    ****************************************************************
    * PROBLEM DESCRIPTION: This APAR fixes several issues:         *
    *                      1.ABENDS0C4 in panels when exiting      *
    *                      with PF3 from panel IQCP94C.            *
    *                      2.Timeout resulting in message :        *
    *                        IQC4065T QCF/IMS conflict             *
    *                       and no results from batch or panel     *
    *                       requests.(this happens if there        *
    *                       is large amount of messages and        *
    *                       QCF is running with low priority)      *
    *                      3.ABEND301 in IQCFCKPT                  *
    ****************************************************************
    * RECOMMENDATION: 1.ABEND0C4 IN ISPF ISPDTD WHEN EXITING(PF3)  *
    *                  QCF PANEL IQCP94C - several CONTROL         *
    *                  commands left in the programs-not needed    *
    *                 2. Online query getting message:             *
    *                   IQC4065T QCF/IMS conflict.                 *
    *                 and no results out of batch and panel's      *
    *                 actions, when there is a large amount        *
    *                 of messages on the queues and low priority.  *
    *                 We are adding new parameter to server        *
    *                 start up member- WAITTIME=nnn - in seconds.  *
    *                 If this parameter is missing- default        *
    *                 wait time is 60 secs. If the parameter is    *
    *                 <= 6 , it is set to default = 60 secs.       *
    *                 New server sample start uo member is:        *
    *                 IMSPLEX=PLEX1                                *
    *                 AUTH=N                                       *
    *                 DEBUG=N                                      *
    *                 WAITTIME=120                                 *
    *                 3. Abend in IQCFCKPT - wrong label in close  *
    *                 output file.                                 *
    ****************************************************************
    The 3 issues are fixed and the samples are updated.
    

Problem conclusion

  • Programs are fixed, samples are updated.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK68317

  • Reported component name

    IMS QUEUE CNTL

  • Reported component ID

    5697E9900

  • Reported release

    310

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2008-06-27

  • Closed date

    2008-08-21

  • Last modified date

    2022-12-15

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK39160

Modules/Macros

  •    IQCBTQCF IQCCTIME IQCC010  IQCFCKPT IQCP2200
    IQCSERVI IQCZCIB  IQCZMSGO IQCZPAR0 IQCZQAB  IQCZSAF0 IQCZTSOA
    

Fix information

  • Fixed component name

    IMS QUEUE CNTL

  • Fixed component ID

    5697E9900

Applicable component levels

  • R310 PSY UK39160

       UP08/08/23 P F808

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8A6","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0"}]

Document Information

Modified date:
15 December 2022