PM18428: YOU RECEIVE A RESP(16)RESP2(30) WHEN ISSUING A PUT-CONTAINER FOR DFHWS-RESPWAIT BECAUSE IT HAS BEEN DEFINED READONLY.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as unreproducible.

Error description

  • You are trying to alter the contents of container DFHWS-RESPWAIT
    by calling a handler program during pipeline processing on an
    INVOKE WEBSERVICE. The handler program does a PUT-CONTAINER for
    DFHWS-RESPWAIT and it fails with a RESP(16) RESP2(30) indicating
    INVREQ, You tried to write to a CICS-defined read only
    container. Reviewing the trace, shows that there when the
    container is created, USERACCESS(READONLY) is being set.
    DFHWS-RESPWAIT should be able to read/write and not readonly.
    

Local fix

  • KIXREVRJL
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All                                          *
    ****************************************************************
    * PROBLEM DESCRIPTION: EXEC CICS PUT CONTAINER to container    *
    *                      DFHWS-RESPWAIT fails with INVREQ RESP2  *
    *                      = 30.                                   *
    *                                                              *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    A requester pipeline handler program is trying to alter the
    contents of container DFHWS-RESPWAIT. The handler program does a
    EXEC CICS PUT CONTAINER for DFHWS-RESPWAIT and it fails with a
    RESP(16) RESP2(30) indicating INVREQ, the program is trying to
    alter a CICS defined read only container. This is because when
    DFHPIPM initially sets up the DFHWS-RESPWAIT container, it did
    not clear the DFHPGCR parameter list. USERACCESS(READONLY) was
    still set in the parameter list from a previous PUT CONTAINER
    request. This causes DFHWS-RESPWAIT to be READONLY when it
    should be a normal read/write container.
    

Problem conclusion

Temporary fix

  • FIX AVAILABLE BY PTF ONLY
    

Comments

  • DFHPIPM has been altered to clear the DFHPGCR parameter list
    before calling put_container_bit to put the RESPWAIT value
    into container DFHWS-RESPWAIT.
    

APAR Information

  • APAR number

    PM18428

  • Reported component name

    CICSTS V3 Z/OS

  • Reported component ID

    5655M1500

  • Reported release

    500

  • Status

    CLOSED UR3

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-07-14

  • Closed date

    2010-08-27

  • Last modified date

    2010-10-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK60133

Modules/Macros

  •    DESPIPM  DFHPIPM
    

Fix information

  • Fixed component name

    CICSTS V3 Z/OS

  • Fixed component ID

    5655M1500

Applicable component levels

  • R500 PSY UK60133

       UP10/09/03 P F009

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2","Edition":"","Line of Business":{"code":"","label":""}}]