IBM Support

PM17928: DATABASE THAT IS STOPPED AT THE START OF ORF IS NOT RESTARTED

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as new function.

Error description

  • This APAR will address the following issues/enhancements:
    - ORF needs a method to start a database that was stopped when
      ORF started.
    - Currently there is no method to limit the number of WTORs
      issued to stop BMPs.
    - ORF needs a way to surpress dump intercepting software so
      problems can be analyzed properly.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: User's of IMS Online Reorg Facility V1.2     *
    ****************************************************************
    * PROBLEM DESCRIPTION: ORF needs a method to start a database  *
    *                      that was stopped when ORF was started.  *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    This APAR is adding the following enhancements:
    1.  DBSTART=Y|N
     When a database is stopped prior to ORF, it will remain stopped
     at the end of ORF.  This can be overridden by:
      Specifying DBSTART=Y|N in HRFSETOP and/or
      specifying DBSTART(Y|N) in the HRFSYSIN control cards.
     The specification in HRFSETOP will serve as a default, which
    maybe overidden by the specification in the HRFSYSIN control
    cards.
    "N" will not start the database if the database was stopped
    prior to the ORF job; This is the default in HRFSETOP.
    "Y" will start the database in takeover, even if the database
    is found prior to the ORF job.
    2.  BMPRETRY=nnn
    When a WTOR is issued to stop BMPs, it will be repeated
    every 10 seconds.
    There is currently no limit on those repeats prior to this
    option.  BMPRETRY can now be specified in HRFSETOP (it is not
    allowed on HRFSYSIN).
    It is a numerical value that specifies how many retries
    are accepted (nnn * 10 seconds).
    When that number is exceeded, ORF will terminate with an
    error message (HRF01570E Waiting for BMPs has expired) and
    the original database will be made available again in the
    same state before ORF started.
    3. When dump intercepting software is installed, ORF now
    suppresses those by dynamically allocating the appropriate DD
    statement to allow the dump to be produced. This is currently
    in affect for ABENDAID and DUMPMASTER.
    

Problem conclusion

Temporary fix

Comments

  • The has been modified to add the above enhancements.
    

APAR Information

  • APAR number

    PM17928

  • Reported component name

    IMS ONLINE REOR

  • Reported component ID

    5655H9700

  • Reported release

    120

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2010-07-06

  • Closed date

    2010-07-12

  • Last modified date

    2013-03-13

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK58756

Modules/Macros

  • HRFOAPLY HRFOLEV0 HRFOREO0 HRFOREO2 HRFOREO3
    HRFOREO8 HRFSET   HRFYCCDF HRFYSTRT
    

Fix information

  • Fixed component name

    IMS ONLINE REOR

  • Fixed component ID

    5655H9700

Applicable component levels

  • R120 PSY UK58756

       UP10/08/04 P F008

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89V","label":"IMS Online Reorganization Facility"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"120","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: