APAR status
Closed as program error.
Error description
The problem is triggered by the EHOSTUNREACH error (113) while r eading the data from the socket. Normally, the EHOSTUNREACH err or is given when writing to a socket, however, for some reason, LINUX socket implementation returns that error when reading from the socket under some unknown conditions. Since we don't how to handle such error (i.e.retry later or close the socket), it was returned as an 'u nknown' network error. When the objreg and router get those 'unknown' errors, they trea t it as some kind of network glitch and, therefore, they wait (s leep) for few seconds before continue other network activities.
Local fix
Problem summary
EHOSTUNREACH error (113) socket error on Linux causes objreg and router problems
Problem conclusion
The issue has been fixed for 6.4_sp1_patch release.
Temporary fix
Comments
APAR Information
APAR number
PM14242
Reported component name
TLOGIC SYNERGY
Reported component ID
5724V66SN
Reported release
710
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-05-11
Closed date
2010-06-03
Last modified date
2010-06-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TLOGIC SYNERGY
Fixed component ID
5724V66SN
Applicable component levels
R710 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSC6Q5","label":"Rational Synergy"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.1","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date: