A fix is available
APAR status
Closed as program error.
Error description
Occurrence of the messages FPEV0266I ... EXCEPTION PROCESSING DIAGNOSTIC DATA: DB2 TIMEOUT FPEV0267I ... EXCEPTION PROCESSING DIAGNOSTIC DATA: RA PRESERVED FOR LATER USE followed byeither 1) ABEND S0C4-04 or 2) the message FPEV0560E DBW1 DB2 RETURNED INCORRECT DATA. REQUEST CANCELED along with ABEND S102 (a SVC dump with the title "INCORRECT RA - DB2I" is captured)
Local fix
n/a
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component: * * - OMEGAMON collector * * - PE Server subtask * * - Classic Interface * * - ISPF Monitoring dialogs * * - Performance Expert Client * * - Performance Expert Agent for * * DB2 Connect Monitoring * **************************************************************** * PROBLEM DESCRIPTION: Occurrence of the messages * * FPEV0266I ... EXCEPTION PROCESSING * * DIAGNOSTIC DATA: DB2 TIMEOUT * * and * * FPEV0267I ... EXCEPTION PROCESSING * * DIAGNOSTIC DATA: RA PRESERVED FOR * * LATER USE * * followed by the abend S0C4-04 (or/and * * S102) in the module FPEVDB2I. * * A corresponding instance of PE Server * * subtask monitoring the DB2 subsystem * * given is stopped. * * * * * **************************************************************** * RECOMMENDATION: Apply this PTF * * When the messages FPEV0266I and FPEV0267I * * come up in JES outputs of a corresponding * * OMEGAMON Collector started task, take prompt * * actions to locate and eliminate timeouts in * * corresponding DB2 subsystems. * * Neglecting of this requirement may cause * * the PE Server subtasks to terminate. * * * * * **************************************************************** PROBLEM SUMMARY: Occurrence of a timeout in a DB2 subsystem being monitored by PE Server subtask causes inoperability of all kind of clients interacting with this PE Server subtask and later on the abend S0C4-04 in the module FPEVDB2I occurs. OMEGAMON Collector started task must be recycled. PROBLEM CONCLUSION: The code of PE Server subtask has been modified to solve this problem.
Problem conclusion
The code of PE Server subtask has been modified to solve this problem. KEYWORDS : FPEV0266I FPEV0267I S0C4-04 IN FPEVDB2I
Temporary fix
Comments
APAR Information
APAR number
PM12378
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
420
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-04-15
Closed date
2010-07-06
Last modified date
2010-08-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK58559
Modules/Macros
DGOVABAN DGOVMSTR FPE@DB2I FPEVDB2I
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R420 PSY UK58559
UP10/07/09 P F007
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date: