APAR status
Closed as program error.
Error description
Windows Server 2003 64 bit System Architect v11.3.1 Impact: Unable to upgrade from 11.2 to work on a new project Expected Results: To be able to install System Architect v11.3.1 on a 64 bit operating system Actual Results: During the installation of the prerequisites for System Architect v11.3.1, the installation fails. Specifically , the 'Microsoft SQL Server 2005 Backawards compatibility'. Error message when attempting to install the prerequisite via SA 's installation: 'The installation of Microsoft SQL Server 2005 Backward compatib lity 64 bit has failed. Setup will now exit.' Steps to reproduce: 1. Run the RatlSysArch_11-3-1.exe on a Windows Server 2003 64 bi t NOTE: The problem was confirmed by Duncan and Sudarshan. The problem is that installer looks for the 32 bit version of the Microsoft SQL Server 2005 Backwards Compatibility and not the 64 bit versi on.
Local fix
Problem summary
During the installation of the prerequisites for System Architect v11.3.1, the installation fails. Specifically, the "Microsoft SQL Server 2005 Backawards compatibility".
Problem conclusion
Fixed with internal CR# 55580 in version 11.3.1.1: Microsoft SQL Server 2005 Backward compatibility 64 bit prerequisite checking wrong registry key The Microsoft SQL Server 2005 Backward compatibility 64 bit.prq file checks the registry to see if it needs to be installed (and whether it has been successfully installed). We don't support 64bit installations officially, but the installer does try to work; so this should be fixed. Just need to change the registry key being checked.
Temporary fix
Comments
APAR Information
APAR number
PM11706
Reported component name
TLOGIC SYS ARCH
Reported component ID
5724V68SA
Reported release
B31
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-04-07
Closed date
2010-04-09
Last modified date
2010-04-09
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TLOGIC SYS ARCH
Fixed component ID
5724V68SA
Applicable component levels
RB31 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS6RBX","label":"Rational System Architect"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"11.3.1","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
09 April 2010