A fix is available
APAR status
Closed as program error.
Error description
The following errors were received applying PTF UK49536: - MSGIEW2635I in link edit of IZTUDAT0. Caused by uneeded EODAD= in DCB Defintion in RMODE(ANY) module IZTUDAT1. - MSGIEW2456E in link edit of IZTCLN00 due to missing CSECT IZTCOMP00. Caused by PK84996 having included JCLIN to add the CSECT to IZTCLN00 but not updating the IZTCOMP0 CSECT to actually link edit the module. - MSGIEW2480W in link edit of IZTUD1U0 due to duplicate entry names DLICHKP0 and DLIROLB0. Caused by unused CSECT DLIDB1M2. - MSGIEW2456E in link edit of IZTUD1U0 due to missing CSECT ALLHEXFF. Caused by unused CSECT INIDB1D0. - The ETO Support manuals do not clearly identify the requirement for the IMS Extended Terminal Option (ETO) feature of IMS. - ABEND0C1 IZTLGFXB or any ABEND0C1 because of an unresolved address.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of IMS ETO Support V3.1 * **************************************************************** * PROBLEM DESCRIPTION: Several LINKEDIT errors applying * * PTF UK49536 * **************************************************************** * RECOMMENDATION: * **************************************************************** The following problems are being addressed in this APAR: 1. Batch update utility not properly setting all flags when SLU2/3270 GLOBAL Device record updated. This can cause ETO Support to ignore options specified in only the Global options. 2. Message IEW2635I in link edit of IZTUDAT0 caused by unneeded EODAD= in DCB definition in RMODE(ANY) module IZTUDAT1. 3.Message IEW2456E in link edit of IZTCLN00 due to missing CSECT IZTCOMP0. Caused by PK84996 having included JCLIN to add the CSECT to IZTCLN00 but not updating the IZTCOMP0 CSECT to actually link edit the module. 4. Possible S0C1 abend in the IMS control region if PK84996 is applied with the return code 8 (message IEW2456E) from the SMPE apply. 5. Message IEW2480W in link edit of IZTUD1U0 due to duplicate entry names DLICHKP0 and DLIROLB0. Caused by unused CSECT DLIDB1M2. 6. Message IEW2456E in link edit of IZTUD1U0 due to missing CSECT ALLHEXFF. Caused by unused CSECT INIDB1D0. 7. The ETO Support manuals do not clearly identify the requirement for the IMS Extended Terminal Option (ETO) feature of IMS.
Problem conclusion
The batch update utility has been corrected to properly set the flags in the SLU2/3270 Device GLOBAL record. Also, module IZTCOMP0 has been updated, so it will now get included in the SMPE Bind.
Temporary fix
Comments
APAR Information
APAR number
PM10408
Reported component name
IMS ETO SUPPORT
Reported component ID
5655E1200
Reported release
310
Status
CLOSED PER
PE
YesPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-03-19
Closed date
2010-04-02
Last modified date
2010-05-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK55814
Modules/Macros
IZTBOPD0 IZTBTTD0 IZTCOMP0 IZTGENX IZTMTRX0 IZTNDMXA IZTNDMXB IZTNDMX7 IZTNDMX8 IZTNDMX9 IZTPPUEA IZTPPUEB IZTPPUEZ IZTPPUE7 IZTPPUE8 IZTPPUE9 IZTUDAT1 IZTUD1U0 IZTUXITZ IZTYDRUA IZTYDRUB IZTYDRU7 IZTYDRU8 IZTYDRU9 IZTYPRXA IZTYPRXB IZTYPRX7 IZTYPRX8 IZTYPRX9
| SC18903603 | GI10854701 |
Fix information
Fixed component name
IMS ETO SUPPORT
Fixed component ID
5655E1200
Applicable component levels
R310 PSY UK55814
UP10/04/04 P F004
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX897","label":"IMS ETO Support"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
04 May 2010