Error description

  • The GLXILXE macro is missing from the SGLXMAC causing
    assembly error when compiling an input member using
    the  GLXIEXIT macro. We use the load module method for
    defining exit routine definitions.
    We receive undefined operation code GLXIE / GLXILXE.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Generic Logger Exit users who use LOAD       *
    *                 method to define user exits                  *
    ****************************************************************
    * PROBLEM DESCRIPTION: Assembly error Generic Logger Exit      *
    *                      member GLXIEXIT0                        *
    *                      ERROR ASMA057E UNDEFINED OPERATION CODE *
    *                      - GLXIE/GLXILXE                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    GLXILXE macro was not shipped with GLX causing the assembly
    error
    

Problem conclusion

  • GLXILXE is now shipped and becomes part of SGLXMAC library
    
    This apar also added code to prevent Generic Exits to call
    itself if the users mistakenly define GE in its own PROCLIB
    member
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM08287

  • Reported component name

    IMS TOOLS BASE

  • Reported component ID

    5655V9300

  • Reported release

    110

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2010-02-22

  • Closed date

    2010-02-24

  • Last modified date

    2010-03-01

  • APAR is sysrouted FROM one or more of the following:

    PM05641

  • APAR is sysrouted TO one or more of the following:

    UK54658

Modules/Macros

  •    GEXIINTA GEXIINTB GEXIINTX GEXIINT9 GEXIMSCA
    GEXIMSCB GEXIMSCX GEXIMSC9 GEXQSSP0 GLXILGX0 GLXILXE  GPRIPUE0
    

Fix information

  • Fixed component name

    IMS TOOLS BASE

  • Fixed component ID

    5655V9300

Applicable component levels

  • R110 PSY UK54658

       UP10/02/27 P F002

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCJN3E","label":"IBM Tools Base"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.1.0"}]

Document Information

Modified date:
19 October 2020