APAR status
Closed as program error.
Error description
Environment: Windows Product name: IBM? Rational? Business Developer Program Version : 7.1.0.4 Description. Variables values of Unicode hex values are incorrectly represent ed by the EGL debugger. With an EGL source code module which converses lower case charac ters to uppercase or removes specials characters with the univer sal equivalent, to make the conversion possible a table is initi alized with Unicode hex values on record level. The generated code outputs the correct values at runtime but whe n stepping through with the EGL debugger the value given for the se variables is interpreted as a single byte character and not a s a Unicode hexadecimal representation.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * **************************************************************** * PROBLEM DESCRIPTION: * **************************************************************** * RECOMMENDATION: * **************************************************************** The code was not saving the literal type (in this case Hex Unicode) when a record was embedded in another record.
Problem conclusion
The code has been changed so that the literal type is now preserved
Temporary fix
Comments
APAR Information
APAR number
PM07363
Reported component name
RATL BUS DEV
Reported component ID
5724S5000
Reported release
710
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-02-11
Closed date
2011-08-10
Last modified date
2011-08-10
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL BUS DEV
Fixed component ID
5724S5000
Applicable component levels
R710 PSN
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMQ79","label":"Rational Business Developer"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]