Error description
When doing a copy project operation from a static project hierar chy without checking out (all) subprojects, a static copy of a s ubproject that is not checked out is written to the work area. When doing this on a Windows client, if the static subproject ha s 'translate ascii files' disabled, the ascii files in it will g et translated when written to the static work area. This occurs whether or not the 'no-translate' static subproject has its work area maintained or not. The static work area gets written correctly when the same copy p roject operation is performed from the same prep hierarchy that produces the same static hierarchy via the Create Baseline opera tion.
Local fix
Problem summary
The parent project work area properties are incorrectly used when a static relative subproject is bound into the parent project, so when the parent has translation turned on and the subproject does not, the files under the subproject will be copied to the work area with newline translation.
Problem conclusion
The program was modified to use the subproject's own work area properties when using a static relative subproject under a parent project. Fixed in 7.1.0.1 iFix 02.
Temporary fix
Comments
APAR Information
APAR number
PM06754
Reported component name
TLOGIC SYNERGY
Reported component ID
5724V66SN
Reported release
710
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-02-03
Closed date
2010-04-20
Last modified date
2010-04-20
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TLOGIC SYNERGY
Fixed component ID
5724V66SN
Applicable component levels
R710 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSC6Q5","label":"Rational Synergy"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.1","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]