IBM Support

PM00915: PROVIDE AN OPTION TO GIVE RETURN CODE ZERO FOR A DATA SET THAT IS NOT RENAMED DUE TO AN ENTRY IN EXCLUDE-SRCNAME-MASKS

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • A new keyword is being added to the RENAME command:
    EXCLUDE-SCRNAME( RC( 0 | NOTRENAMED-RC ) )
    This keyword specifies the return code that is to be given for
    data sets that match entries in the EXCLUDE-SRCNAME-MASKS
    keyword.
    The default is RC(NOTRENAMED-RC) which will use the RC value
    from the NOTRENAMED keyword.
    Using RC(0) specifies that a return code of zero will be given
    for data sets that match entries in the EXCLUDE-SRCNAME-MASKS
    keyword.
    Three messages are being updated to give an indication if the
    data set name matches an entry in the EXCLUDE-SRCNAME-MASKS
    keyword:
    CKZ11112W
    CKZ11212W
    CKZ11312W
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of DB2 Cloning Tool.               *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    *                      A new keyword is being added to the     *
    *                      RENAME command:                         *
    *                                                              *
    *                      EXCLUDE-SCRNAME(RC(0 | NOTRENAMED-RC))  *
    *                                                              *
    *                      This keyword specifies the return code  *
    *                      that is to be given for data sets that  *
    *                      match entries in the                    *
    *                      EXCLUDE-SRCNAME-MASKS keyword.          *
    *                      The default is RC(NOTRENAMED-RC) which  *
    *                      will use the RC value from the          *
    *                      NOTRENAMED keyword.                     *
    *                      Using RC(0) specifies that a return     *
    *                      code of zero will be given for data     *
    *                      sets that match entries in the          *
    *                      EXCLUDE-SRCNAME-MASKS keyword.          *
    *                      Three messages are being updated to     *
    *                      give an indication if the data set      *
    *                      name matches an entry in the            *
    *                      EXCLUDE-SRCNAME-MASKS keyword:          *
    *                                                              *
    *                      CKZ11112W                               *
    *                      CKZ11212W                               *
    *                      CKZ11312W                               *
    *                                                              *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF.                               *
    ****************************************************************
    Code has been changed to correct this condition.
    

Problem conclusion

  • Apply the PTF.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM00915

  • Reported component name

    DB2 CLONING TOO

  • Reported component ID

    5655N1000

  • Reported release

    210

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-11-10

  • Closed date

    2009-12-01

  • Last modified date

    2010-01-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK52438

Modules/Macros

  •    CKZ00100 CKZ00110 CKZ00111 CKZ00112 CKZ00113
    CKZ00114 CKZ00115 CKZ00116 CKZ00117 CKZ00130 CKZ00135 CKZ00140
    CKZ00141 CKZ00150 CKZ00400
    

Publications Referenced
SC19122001    

Fix information

  • Fixed component name

    DB2 CLONING TOO

  • Fixed component ID

    5655N1000

Applicable component levels

  • R210 PSY UK52438

       UP09/12/05 P F912

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAUUE","label":"IBM Db2 Cloning Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
12 February 2021