Error description
The DB2 Object Comparison Tool for z/OS' IGNORE feature did not prevent a table being dropped and created when a difference in the number of partitions was present and the GENERIC IGNORE PARTITIONING was used. This resulted in a message: Tables have identical column lists (D)Number of partitions reduced by 100 partition(s) Table aaa.aaa will be dropped Table will be recreated Table data will not be converted
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of DB2 Object Comparison * * Tool for z/OS who use the ignore * * partitioning option and/or table * * columns with NOT NULL WITH * * DEFAULT constant. * **************************************************************** * PROBLEM DESCRIPTION: The compare of the table did * * not fully ignore partitioning. * * Modifications to column * * NOT NULL WITH DEFAULT * * constants were not * * implemented correctly. * **************************************************************** * RECOMMENDATION: Apply The PTF. * **************************************************************** DB2 Object Compare reported changes in table partitioning which resulted in a DROP/CREATE of the table. Modifications to column NOT NULL WITH DEFAULT constants were implemented with DROP/CREATE.
Problem conclusion
DB2 Object Compare is changed to correctly handle this situation. Changes were also made to support the smart alter of columns NOT NULL WITH DEFAULT constant.
Temporary fix
Comments
APAR Information
APAR number
PK98414
Reported component name
DB2 OBJECT COMP
Reported component ID
5697G6400
Reported release
720
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-10-12
Closed date
2010-04-22
Last modified date
2010-05-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
GOC2CMF GOC2CMT
Fix information
Fixed component name
DB2 OBJECT COMP
Fixed component ID
5697G6400
Applicable component levels
R720 PSY UK56303
UP10/04/28 P F004
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAUVH","label":"IBM Db2 Object Comparison Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"720","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
12 February 2021