IBM Support

PK94878: ALLOW RECOVERDM PROCEDURE TO START WITH A /STA REG VIA THE INTERNAL READER INSTEAD OF JUST THE Z/OS START COMMAND

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as new function.

Error description

  • Allow the RECOVERDM procedure to start with a /STA REG command
    via the Internal Reader instead of just the z/OS start command.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of QCF3.1. The changes affect      *
    *                 actions on IMS cold and warm start. Problems *
    *                 with selection of DEADQ queue types are      *
    *                 fixed, code is added to release the          *
    *                 overflow protection files after editing      *
    *                 the members.                                 *
    ****************************************************************
    * PROBLEM DESCRIPTION: 1.New parameter is added to ONCOLDSTAR  *
    *                      and ONWARMSTART in IMS contro reagion   *
    *                      start up configuration member.          *
    *                      On IMS WARMSTART                        *
    *                      On IMS COLDSTART                        *
    *                      Perform the function                    *
    *                      requested in PROCNAME/JOBNAME/STARNAME  *
    *                      STARNAME:                               *
    *                        1- to 8-character proclib member name *
    *                        IMS QCF will issue internal command   *
    *                        /STA REG and the job will be started  *
    *                        via IMS internal reader.              *
    *                      2.QUEUTYPE=DEADQ selection did not work *
    *                      in combination with SELECT statement.   *
    *                      This restriction has been removed.      *
    *                      3.Data sets with overflow protection ar *
    *                      released after editing members- now the *
    *                      can be allocated to started jobs.       *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    - Programs have been changed to add a new action type to
    ONCOLDSTART and ONWARMSTART - action start region.
    The new STARNAME=..parameter is used to issue an internal
    /STA REG command to submit the job via the internal IMS reader.
    - QUEUTYPE=DEADQ selection did not work
    in combination with SELECT statement.
    This restriction has been removed.
    - Data sets with overflow protection are
    released after editing members- now they
    can be allocated to started jobs.
    

Problem conclusion

Temporary fix

Comments

  • Install the APAR, change the control region start up member and
    recycle IMS, server and client interface.
    

APAR Information

  • APAR number

    PK94878

  • Reported component name

    IMS QUEUE CNTL

  • Reported component ID

    5697E9900

  • Reported release

    310

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2009-08-27

  • Closed date

    2010-04-08

  • Last modified date

    2010-05-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK55929

Modules/Macros

  •    IQCCCPRM IQCCIN0A IQCCIN0B IQCCIN0X IQCCIN08
    IQCCIN09 IQCCIN1A IQCCIN1B IQCCIN1X IQCCIN18 IQCCIN19 IQCCQAB
    IQCC1ENU IQCIMSII IQCP7100 IQCP8100 IQCSIN10 IQCXREAD IQCZDYN0
    

Fix information

  • Fixed component name

    IMS QUEUE CNTL

  • Fixed component ID

    5697E9900

Applicable component levels

  • R310 PSY UK55929

       UP10/04/09 P F004

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8A6","label":"IMS Queue Control Facility"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0"}]

Document Information

Modified date:
03 October 2020