A fix is available
APAR status
Closed as program error.
Error description
The DB2 Object Comparison Tool for z/OS issues a message: Compare table source(aaaaaaa.aaaaaaaaaaaaaaaa) and target(aaaaaaa.aaaaaaaaaaaaaa Column aaaaaaaaaaaaa (D)Field OWNERTYPE changed from ' ; 0 346 CB ᆰH } to ' ) ; 0 Tables have identical column lists Table aaaaaaa.aaaaaaaaaaaaaaaa will be dropped Table will be recreated even when the SYSTABLES OWNER and OWNERTYPE IGNORE's are specified. SYSCOLUMNS does not have an OWNERTYPE IGNORE available.
Local fix
None as manually coding an IGNORE of: SYSCOLUMNS:OWNERTYPE results in the job ending RC12 and the message: GOCC007E - Invalid field name in IGNORES file record n
Problem summary
**************************************************************** * USERS AFFECTED: Users of DB2 Object Comparison Tool. * **************************************************************** * PROBLEM DESCRIPTION: Object Comparison reports OWNERTYPE * * change under column name while there * * is no such change. The table is * * dropped/recreated. * * * * Specifying OWNERTYPE in the IGNORE data * * set does not help. Additional problem: * * message "ADBDICT:Key already exists". * **************************************************************** * RECOMMENDATION: Apply The PTF. * **************************************************************** Object Comparison reports incorrectly OWNERTYPE change and drops/recreates the table. Additional problem: message "ADBDICT:Key already exists".
Problem conclusion
Both problems have been fixed.
Temporary fix
Comments
APAR Information
APAR number
PK94220
Reported component name
DB2 OBJECT COMP
Reported component ID
5697G6400
Reported release
720
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-08-19
Closed date
2009-09-20
Last modified date
2009-10-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
GOC2CMP GOC2CMR GOC2CMS GOC2CMT
Fix information
Fixed component name
DB2 OBJECT COMP
Fixed component ID
5697G6400
Applicable component levels
R720 PSY UK50282
UP09/09/26 P F909
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAUVH","label":"IBM Db2 Object Comparison Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"720","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date: