IBM Support

PK92931: RHAPSODY CAUSES FATAL ERROR WHILST CODE GENERATION.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Quintus: 225934
    
    One of our customer - is encountering Rhapsody fatal
    error during code generation.  They originally have used
    Rhapsody 7.3.  I reproduced the issue 7.5
    
    Attached is a zip file that contains two Rhapsody models, and
    some RER files created whilst the error.
    - p1_p_timer.zip    (A model to reproduce the issue)
    - p4_s_request.zip  (A model to reproduce the isseu)
    - RER_p1_p_timer.zip   (Error log whilst using p1_p_timer)
    - RER_p4_s_request.zip (Error log whilst using p4_s_request)
    
    According to the customer, same/similar symptom occurs by using
    the other models.  I also have atteched a zip file that contains
    multiple RER files sent from the customer:
    - RER.zip
    - RER2.zip
    
    Followings are the steps to reproduce.  Please note that the
    symptom not always occur.  You have to repeat regenerating
    multiple times.  So, please be patient.  I have tried on my VM
    with 512MB and had to regenerate 5 to 20 times to repsoduce the
    issue.
    
    ***** using p1_p_timer
    (1) Start Rhapsody and open the model.  (I tried Rhapsody 7.5)
    (2) Using the Rhapsody Browser, expand 'p_timer ? Components ?
    sim ? Configurations'.
    (3) Right-click 'Animation' and select 'Generate Configuration
    Main and Makefiles'.
        (Rhapsody will show and error message due to lack of
    'Animation.cg_info'.  Ignore the message by clicking [Yes].)
    (4) After the generation is done, select menu 'Code ? Re
    Generate ? Animation'.
    (5) Repeat the operation (4) after the previous generate is
    done.
    
    Whilst regenerating the code, Rhapsody will display the
    following error dialog box:
    ?????
    Title: Rhapsody
    Message:
    Fatal error occurred while invoking Code Generation.
    Please 'Save As' your model and close Rhapsody.
    ?????
    After clicking-
    
    ***** using p4_s_request
    (1) Start Rhapsody and open the model.
    (2) Select menu 'Code ? Re Generate ? None'.
    (3) After the previous generateion ends, repeat (2).
    
    Whilst regenerating the code, Rhapsody will display the
    following error dialog box:
    ?????
    Title: Rhapsody
    Message:
    Fatal error occurred while invoking Code Generation.
    Please 'Save As' your model and close Rhapsody.
    ?????
    

Local fix

  • It is reported that deleting source code folder before generate
    will avoid the error.
    

Problem summary

  • RHAPSODY CAUSES FATAL ERROR WHILST CODE GENERATION.
    

Problem conclusion

  • Fixed in 7.5.1
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK92931

  • Reported component name

    TLOGIC RHAPSODY

  • Reported component ID

    5724V74RP

  • Reported release

    730

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-08-03

  • Closed date

    2011-05-03

  • Last modified date

    2011-05-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC RHAPSODY

  • Fixed component ID

    5724V74RP

Applicable component levels

  • R751 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS7P9W","label":"Rational Rhapsody"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.3","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]