Error description
TST:1068517 Summary: -------- Error while running a TCHK exe for mastermind Description: ------------ When trying to run the exe from Testchecker a following runtime error is observed as shown in the screenshot. From the error message, we suspect that runtime libraries not loading correctly. This error is only observed with VC8 installed on the system. The same steps does not show any errors with vc6 and vc7. Customer has a work around now, They have changed the order in which makelog.bat looks for the installed compilers. And have changed it from if exist "%VC8%" goto vc8 if exist "%VC7%" goto vc7 if exist "%VC6%" goto vc6 to if exist "%VC7%" goto vc7 if exist "%VC6%" goto vc6 if exist "%VC8%" goto vc8 This is working for the moment, however customer has to use an older compiler. Version Details: Logiscope: 6.5 and 6.6 OS: Windows xp Compiler: vc8 Steps to Reproduce: ------------------- 1. Open Testchecker Mastermind with Logiscope 6.5/6.6 2. Build the project. 3. Launch Testchecker. 4. Select the Test tab 5. Create a new test 'File->new' and then 'Edit-> New Tests'. 6. Select the new test and select any metric from the view, eg: DDP SPY. 7. Press Go and observe the behavior. Support Observations: --------------------- We were able to observe the same behavior at our support labs.We suspect that Logiscope is not loading the runtime libraries correctly for vc8. If we use vc6 or vc7 the error is not observed. Customer has changed the makelog.bat so that it looks for vc6 and vc7 before vc8. However this means that they will have to use an older compiler. We are of the opnion that this behavirois a defect. Please let us know if there is any solution for the same.
Local fix
Customer has a work around now, They have changed the order in which makelog.bat looks for the installed compilers. And have changed it from if exist "%VC8%" goto vc8 if exist "%VC7%" goto vc7 if exist "%VC6%" goto vc6 to if exist "%VC7%" goto vc7 if exist "%VC6%" goto vc6 if exist "%VC8%" goto vc8 This is working for the moment, however customer has to use an older compiler.
Problem summary
This defect is fixed in Logiscope 6.6.1. This information is available in the release notes.
Problem conclusion
Temporary fix
Comments
APAR Information
APAR number
PK91801
Reported component name
TLOGIC LOGISCOP
Reported component ID
5724V81LS
Reported release
650
Status
CLOSED FIN
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-07-20
Closed date
2009-10-23
Last modified date
2010-01-14
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
R660 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSYQHS","label":"Rational Logiscope"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.5","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
14 January 2010