PM42543: QCI 3.5 sync error on empty module

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When using DOORS/Quality Center Interface 3.4.0.2, if you try to
    sync an empty module from DOORS to QC, it completes with no
    errors. It simply says 0 objects created/modified in the report.
    
    
    Now if you try to run a full or incremental sync using
    DOORS/Quality Center Interface 3.5 with an empty DOORS module
    the following happens:
    1) In the admin tool it appears that the 'Executing task' window
    goes on forever with it being stuck at the 'Retrieving
    configuration data ...' step
    2) The actual task summary says the outcome is an error and
    there are DXL errors
    3) checking the DOORS* log file for DXL errors you see:
    -R-E- DXL: ?addins/doorstdint/tdsync.inc:1818? unassigned
    variable (obj)
    Backtrace:
     ?addins/doorstdint/tdsync.inc:1818?
     ?Line:3?
    -I- DXL: execution halted
    -E- DOORS: DXL halted with run-time error
    
    
    I would expect the 3.5 interface to run the same way as 3.4.0.2.
    To complete successfully and not sync any objects since the
    module is empty.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    n/a
    

Problem conclusion

  • n/a
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM42543

  • Reported component name

    TLOGIC DOORS

  • Reported component ID

    5724V61DR

  • Reported release

    930

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-06-27

  • Closed date

    2012-03-30

  • Last modified date

    2012-03-30

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC DOORS

  • Fixed component ID

    5724V61DR

Applicable component levels

  • R930 PSN

       UP