PM41837: ABEND0C4 LMOD=KO2DWTRB OFFSET=1992 CSECT=O2DCS2

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • abend0c4 in  LMOD=KO2DWTRB#L, CSECT=#UNKNOWN, OFFSET=001992
    .
    DUMP SHOWS:
    .
    SEARCH ARGUMENT ABSTRACT
    .
    RIDS/KO2DWTRB#L RIDS/#UNKNOWN AB/S00C4 PRCS/00000004 REGS/0A0F2
    .
    Symptom                               Description
    ---------------          ---------------------------------------
    .
    RIDS/KO2DWTRB#L           Load module name: KO2DWTRB
    RIDS/#UNKNOWN             Csect name: #UNKNOWN
    AB/S00C4                  System abend code: 00C4
    PRCS/00000004             Abend reason code: 00000004
    REGS/0A0F2                Register/PSW difference for R0A: 0F2
    .
    CPU STATUS:
    PSW=078D2000 9A624A12
      (Running in PRIMARY, key 8, AMODE 31, DAT ON)
      DISABLED FOR PER
    ASID(X'0173') 1A624A12. KO2DWTRB+1992 IN EXTENDED PRIVATE
    ASID(X'0173') 1A624A12. AREA(Subpool252Key00)+1A12 IN EXTENDED
                                                          PRIVATE
    .
    PSW 9A624A12 points to:
    .
    ..  *** COPYRIG
     HT (C) 1977,1988
     - 2010 IBM CORP
     ORATION *** ....
     O2DCS2   V510210
     04/16/11 03:58.{
     PM36528 DB2COM
     COMCOM  . COPYRI
    .
    abend0c4 in CSECT KO2DCS2B at PM36528 level at offset+1992.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component:                          *
    *                 -   OMEGAMON collector                       *
    ****************************************************************
    * PROBLEM DESCRIPTION: ABEND0C4 caused by missing TCB address. *
    *                                                              *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF                               *
    *                                                              *
    ****************************************************************
    PROBLEM SUMMARY:
    The TCB address is used to address internal data structures
    during execution of the NTH collector.
    
    PROBLEM CONCLUSION:
    Set the TCB address before calling lower level routines.
    

Problem conclusion

  • Set the TCB address before calling lower level routines.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM41837

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    510

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-06-16

  • Closed date

    2011-09-02

  • Last modified date

    2011-10-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK71578

Modules/Macros

  • KO2HDTPB
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R510 PSY UK71578

       UP11/09/07 P F109

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]