Error description
This APAR is for these following Internal PMRs: ============================================================== PMR 58199,999,000 - JCYMIG00 fix for cloning VSAM files for DISP=OLD Date requested: 05/10/2011 Severity: high Users Affected: New IMU users of JCYMIG00 utility who update VSAM files Problem Description: JCL generated by JCYMIG00 is does not contain IDCAMS for copying VSAM files to a new dataset when DISP=OLD is specified. Problem Summation There is a bug in FSYMIG0 program (called by FSYMIG00). The DISP=OLD is not recognized as a valid disposition for VSAM files accessed in I-O mode. Problem Conclusion: A change was made to FSYMIGS0 recognize DISP=OLD as a valid disposition for VSAM files in I-O mode. Changed programs: FSYMIGS0 - Logic was added to generate UNIT=&TAPE as per //TAPE-UNIT option. ================================================================ ================================================================ PMR 58203,999,000 - JCYMIG00 support for output tape files in EZT Plus step Date requested: 05/10/2011 Severity: high Users Affected: New IMU users of JCYMIG00 utility who create tape files Problem Description: JCL generated by JCYMIG00 is directing output tape files in EZT Plus step to disk. Problem Summation Utility does not provide means of directing the output tape files to tape in EZT Plus step. Problem Conclusion: An option was added to #FJICNTL table to identify UNIT= coded on DD statements. All output files that match UNIT=&unit parameter provided in #FJICNTL via ??//TAPE-UNIT? are generated with such unit name, thus directing the file to tape. Changed programs: FSYMIGS0 - Logic was added to generate UNIT=&TAPE as per //TAPE-UNIT option. FSYMIG00 - Logic was added to capture //TAPE-UNIT option of #FJICNTL Changed control files: #FJICNTL - //TAPE-UNIT was added. See changes in the #FJICNTL. ================================================================ ================================================================ PMR 58206,999,000 - JCYMIG00 support for comparing output tape files Date requested: 05/10/2011 Severity: high Users Affected: New IMU users of JCYMIG00 utility who use the Automated Parallel Test utility with tape files Problem Description: The parallel test job is failing to allocate tape files that were created by the IMU step. This failure is occurring in the COMPARE step. Problem Summation IMU?s Dynamic Allocator module (FSYSVC99) cannot allocate tape files due to system restrictions. Problem Conclusion: Solution is to defer compare to a stand-alone compare. To do so, the FJCOMP0 file in the COMPARE step had to be copied to a permanent file for later use. This is accomplished as follows: 1. New control files, #FJICNT2 for Easytrieve Plus, and #FJECNT2 for EZT Classic, were created to copy FJCOMP0 to a permanent file. These files were created from #FJICNTL and #FJECNTL files. In these new control files, the COMPARE step was completely replaced by IEBGENER that copies the temporary FJCOMP0 to a permanent FJCOMP0 file. 2. An new stand-alone (JCYMIG21) job was created that reads in the FJCOMP0 data set file and generates the required JCL for stand-alone compare for all files in the FJCOMP0 data set. Note that JCYMIG21 generates the stand-alone compare and the purge JCL. See comments in JCYMIG21 for details. Changed programs: FSYMIG21 - New program for generating compare and purge JCL. Used by JCYMIG21. FSYMIG20 - Program was changed to recognize stand-alone compare for files that were generated by the parallel test. FSYCNV20 - Program was changed to recognize stand-alone compare for files that were generated by the parallel test. FSYGTDCB - Support for Long Block Interface (LBI) was added New JCL: JCYMIG21 - generates the stand-alone compare and the purge JCL. See comments in JCYMIG21 for details. New control files: #FJICNT2 - Contains the new COMPARE step that saves the FJCOMP0 to a permanent file. #FJECNT2 - Contains the new COMPARE step that saves the FJCOMP0 to a permanent file. Special instructions for deferring the compare step: 1. Make the necessary changes to #FJICNT2 and #FJECNT2 to reflect your own needs. 2. Point FJICNTL= in JCYMIG00 to use #FJICNT2 or #FJECNT2 respectively 3. Update JCYMIG21 JCL to use: (there are three (4) SET statements in the JCL. a) FJCOMP0 saved by the COMPARE step of #FJICNT2 or #FJECNT2 b) FJICNTL that was used by JCYMIG00 c) The DSN for FJPURGE where purge JCL will be placed. d) Change CLASS=A to whatever job class you wish on the generated compare and purge JCL. e) Change PARM= options on the EXEC PGM=FSYMIG21 to suit your needs. Note that the 1st parameter cannot be changed. 4. JCL for the parallel test is punched to FJCMP20 file. As distributed, this file is punched into internal reader, therefore it is automatically run after the EOJ of JCYMIG21, of course, if the CLASS= is correct. ================================================================ ================================================================ PMR 58211,999,000 - Add support for ALPHATEST=NATIVE/EASYT Date reported: 05/10/2011 Severity: high Users Affected: All IMU users Problem Description: The COBOL ALPHABETIC test is not compatible with Easytrieve Plus. Problem Summation The default COBOL test is for upper and lower case, while Easytrieve Plus tests for upper case only. Problem Conclusion: ALPHATEST=NATIVE/EASYT EZPARAMS/EASYTRAN option was added. Where: EASYT Accepts ALPHABETIC as the only valid test. It is converted to ALPHABETIC-UPPER for Easytrieve Plus compatibility. NATIVE Accepts the following: ALPHABETIC ALPHABETIC-LOWER ALPHABETIC-UPPER The default is ALPHATEST=NATIVE. Changed macros: EASYTRAN EASYOVRD EASYT007 EASYTCBW Impact on existing users The default option is ALPHATEST=NATIVE. When ALPHATEST=NATIVE is specified, the ALPHABETIC-LOWER and the ALPHABETIC-UPPER are recognized as valid tests. Prior to this change, ALPHABETIC-LOWER was translated by IMU as a valid field name, therefore, programs that contain ALPHABETIC-LOWER for a field name, might fail. The chance for this error is remote, however, be alert. This new feature provides for additional IF statement capabilities not available in Easytrieve Plus. ================================================================ ================================================================ PMR 58213,999,000 - Syntax issues with Easytrieve CLASSIC Date reported: 05/10/2011 Severity: high Users Affected: All IMU users of Easytrieve Classic. Problem Description: 1. NF, NO, OF are not recognized a constant when used in IF post relational operator without parentheses. 2. Unpaired parentheses error message when interpreting comments. 3. ?EASYTRAN ? in ?* EASYTRAN: ? test is failing. 4. When line is not specified for LABELS, IMU flags it as an error. 5. SPnn is not recognized as a valid control character on PRINT statement. Problem Summation 1. Logic in IMU never accounted for bit operators to be coded without parentheses 2. A bug in parsing logic 3. An original typo bug 4. IMU Logic is expecting line number 5. SP1, SP2, SP3 are the only recognized control characters Problem Conclusion: 1. Logic was changed to recognized NF, NO and OF as constants when coded post relational operator. 2. The error was corrected 3. The error was corrected 4. A default of 6 was added to to resolve deficiency. 5. A logic was put in to recognize ?SPnn? As a valid control when coded as the 1st argument on the PRINT statement. Changed macros: EZTRV001 Impact on existing users There is no impact on existing users because these conditions were handled as errors. ================================================================ ================================================================ PMR 58214,999,000 - Parentheses not printing on field titles/headings Date reported: 05/10/2011 Severity: high Users Affected: All IMU users Problem Description: When parentheses are in the headings, the field titles do not mach to those produced by Easytrieve Plus Problem Summation EASYT007 macro strips parentheses for parsing when field headings are more than 3 rows deep. In the process it strips parentheses without handling quotes strings. Problem Conclusion: The logic was corrected to get rid of parentheses correctly. ================================================================ ================================================================ PMR 58263,999,000 - FSYGPCB0 trace feature Date reported: 05/18/2011 Severity: n/a Users Affected: All IMU users of MU V3.2 DLI/IMS feature Problem Description: A trace of PCBs is needed when a DBD is not located in the PCB list passed to FSYGPCB0 by DFSRRC00 DLI program. Problem Summation A trace is needed when "FSY003E - FSYGPCB0: DBD XXXXXXXX PCB SEQ XXX CANNOT BE RESOLVED" message is issued due to undefined DBD received from DFSRRC00 DLI/IMS program. Problem Conclusion: A trace to display PCBs received from DLI was implemented. ================================================================
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: IMU users of JCYMIG00 utility who update * * VSAM files. * **************************************************************** * PROBLEM DESCRIPTION: JCL generated by JCYMIG00 is does not * * contain IDCAMS for copying VSAM files * * to a new dataset when DISP=OLD is * * specified. * **************************************************************** * RECOMMENDATION: Apply the PTF. * **************************************************************** A change was made to FSYMIGS0 recognize DISP=OLD as a valid disposition for VSAM files in I-O mode.
Problem conclusion
A change was made to FSYMIGS0 recognize DISP=OLD as a valid disposition for VSAM files in I-O mode.
Temporary fix
Comments
APAR Information
APAR number
PM38384
Reported component name
MIGRATION UTILI
Reported component ID
5697N4400
Reported release
320
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-05-04
Closed date
2011-06-15
Last modified date
2011-07-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
FSY#CNTL FSY#ECT2 FSY#FCNT FSY#ICT2 FSYCNV20 FSYESCBW FSYESORD FSYETRAN FSYET001 FSYET007 FSYGPCB0 FSYGTDCB FSYJCG00 FSYJCG21 FSYMIGS0 FSYMIG00 FSYMIG10 FSYMIG20 FSYMIG21
Fix information
Fixed component name
MIGRATION UTILI
Fixed component ID
5697N4400
Applicable component levels
R320 PSY UK68805
UP11/06/18 P F106
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSY4B9","label":"IBM Migration Utility for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"320","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]