IBM Support

PM36068: HP LOAD JOB GETS ABENDU3762 WHEN PROCESSING HALDB/OSAM WITH DBALLABOVE OPTION IN THE DFSVSAMP DD.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • HP Load job gets ABENDU3762 when processing HALDB/OSAM with
    DBALLABOVE option in the DFSVSAMP DD.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of IBM IMS High Performance Load   *
    *                 for z/OS Version 2 Release 1 (FMID=H1IM210). *
    ****************************************************************
    * PROBLEM DESCRIPTION: ABENDU3762 when processing HALDB OSAM   *
    *                      with DBALLABOVE in the DFSVSAMP DD.     *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    HP Load job gets ABENDU3762 when processing HALDB OSAM with
    DBALLABOVE option in the DFSVSAMP DD.
    To avoid the abend by disabling DBALLABOVE, you need to accept
    this APAR and apply the USERMOD ZZHPL01 which is provided by
    APAR PM37149.
    

Problem conclusion

Temporary fix

Comments

  • ×**** PE11/06/24 PTF IN ERROR. SEE APAR PM42389  FOR DESCRIPTION
    

APAR Information

  • APAR number

    PM36068

  • Reported component name

    IMS HIGH PERF L

  • Reported component ID

    5655E0700

  • Reported release

    210

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2011-03-31

  • Closed date

    2011-05-09

  • Last modified date

    2011-07-11

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK67540

Modules/Macros

  •    FABFLINK HPSRMDA0 HPSRUMD1 H1IM210J
    

Fix information

  • Fixed component name

    IMS HIGH PERF L

  • Fixed component ID

    5655E0700

Applicable component levels

  • R210 PSY UK67540

       UP11/05/10 P F105

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89F","label":"IMS HP Load"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0"}]

Document Information

Modified date: