IBM Support

PM33760: SOME MESSAGES ARE NOT DEFINED IN THE MESSAGE MANUAL

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as documentation error.

Error description

  • 1) Message KO2O1964I is not in the message manual. The message
    text and explanation is listed in the manual under message
    KO2O1963I. Message KO2O1963I in the manual should be changed to
    KO2O1964I.
    
    2) Messages KO2O1963E, KO2I0553E and KO2I0554E are not
    documented in the messages manual
    

Local fix

  • Note Updated message(s) below:
    
    Message:
       KO2O1964I Backlevel Near-Term History data set(s)
       detected. Resetting.
    Explanation:
       Near-term history VSAM data sets from a previous
       version of Near-Term History Data Collector were
       found. These data sets are not compatible with
       the current Near-Term History Data Collector.
    System action:
       The near-term history VSAM data sets are cleared
       and the Near-Term History Data Collector will start.
    User response:
       None.
    
    
    Message:
       KO2O1963E OMEGAMON Server subtask PESERVER not active.
    Explanation:
       PESERVER subtask is not active. It may have been
       stopped with the command   /F <STC_Name>,P PESERVER
       or during initialization, the START PESERVER command
       was not executed or failed.
    System Action:
       Monitoring is not available
    Programmer or Operator Response:
       Start the PESERVER subtask using the command
       /F <STC_Name>,S PESERVER   Insure that message
       FPEV0000I appears during initialization.
    
    
    
    Message:
       KO2I0553E OINT Jobstep Program: pppppppp. OMPE Subsystem
       required
    Explanation:
       Program name 'pppppppp' is the name specified on
       EXEC statement of the STC JCL. OMPE Releases V420 and
       higher require that PGM=KO2ZTOBP is specified on the
       EXEC statement of the STC JCL statement.
    System Action:
       Started Task terminates.
    User Response:
       Specify PGM=KO2ZTOPB on the EXEC statement of the
       STC JCL statement
    
    
    Message:
       KO2I0554E HINT Jobstep Program: pppppppp. OMPE Subsystem
       required.
    Explanation:
       Program name 'pppppppp' is the name specified on
       EXEC statement of the STC JCL. OMPE Releases V420 and
       higher require that PGM=KO2ZTOBP is specified on the
       EXEC statement of the STC JCL statement.
    System Action:
       Started Task terminates.
    User Response:
       Specify PGM=KO2ZTOPB on the EXEC statement of the
       STC JCL statement
    

Problem summary

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    PM33760

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    420

  • Status

    CLOSED DOC

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-02-28

  • Closed date

    2011-04-25

  • Last modified date

    2014-02-19

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]