A fix is available
APAR status
Closed as program error.
Error description
- IMS V12 added new event records, IMS Connect type 1 commands, and IMS Connect configuration member keywords. - An ABEND0C4 can occur when the CEX trace is active and the amount of data to trace is 2 bytes or less than the CEX trace buffer. The abend occurs in module CEXTECL. - If the ISPF session has underscore turned off for input fields, the Operations System view panel and associated help - A loop in module CEXEXRTR can occur in an IMS Connect V910 system when using routing. - Characters in column 72 of BPECFG member can result in following keywords - values being ignored. - In the ISPF definition dialog, using the "S defname" command on the definition list command line to select a definition for edit causes incorrect definition description to be used. can be confusing because two fields appear to be a single field. - Provide a new security feature when CEX is providing security for IMS Connect. This feature allows securing access to the IMS Connect region based upon the IP address of the remote client. - The CEX batch command utility does not support refreshing the security rules used for CEX security. - If Advanced Function is active, but event collection is inactive, CEX security checking is not performed for IMS Connect message exit HWSJAVA0. Additional symptoms: FUN2211I Syntax error at line 101: the input MSC is not a known command FUN2211I Syntax error at line 122: the input RMTIMSCON is not a known command
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of IMS Connect Extentions V2.2 * **************************************************************** * PROBLEM DESCRIPTION: Abend 0C4 in HWS Port task in module * * CEXTECL doing MVCL instruction. * **************************************************************** * RECOMMENDATION: * **************************************************************** This APAR is addressing the following: 1. Abend 0C4 in HWS Port task in module CEXTECL doing MVCL instruction. 2. If the ISPF session has underscore turned off for input fields, the Operations System view panel and associated help can be confusing because two fields appear to be a single field. 3. Provide a new security feature when CEX is providing security for IMS Connect. This feature allows securing access to the IMS Connect region based upon the IP address of the remote client. 4. If Advanced Function is active, but event collection is inactive CEX security checking is not performed for IMS Connect message exit HWSJAVA0. 5. Provide support for the new event records in IMS V12. 6. An 0C4 can occur in module CEXTECL when the CEX trace is active and the output message returned by the message exit XMIT routine is 2 bytes or less than the size of the trace buffer. 7. A loop in module CEXEXRTR can occur in a V910 IMS Connect system when using routing. 8. Characters in column 72 of BPECFG member can result in following keywords/values being ignored. 9. In the ISPF definitions dialog, using the "S defname" command on the definition list command line to select a definition for edit causes incorrect definition description to be used.
Problem conclusion
1. An abend 0C4 can occur in CEXTECL when CEX tracing is active and the inbound message is exactly the length of the trace buffer. The amount of trace buffer calculation is incorrect causing the MVCL length to go negative and this results in a storage overlay and likely 0C4. 2. Change the design of the Operations Systems panel to make it clearer that these are two input fields instead of one when underscore is turned off for input fields. 3. Provide the ability to setup RACF or other security system profiles that protect IPV4 or IPV6 IP addresses a remote client might use to gain access to the IMS Connect system. CEX will verify that the UID associated with the input transaction is authorized to use the IMS Connect system based upon it's input IP address. 4. Changed module CEXTECL to provide the information necessary for security checking for message exit HWSJAVA0 event if CEX event collection is inactive. 5. Support is added for the new event IMS Connect event records provided in IMS V12. This is early support and limited to the new event records. 6. Corrected the CEXTECL MSGTRC routine to detect the condition where the output message is within 2 bytes of the length of the trace buffer and prevent the abend 7. The V910 XIB is much different than the V10 or later XIB and CEX was not properly determining that the execution version was V910 and this caused a loop trying to check the status of datastores. A change has been made to properly detect a V910 system and use the proper XIB definitions for status checking. 8. Changed parser to correctly handle characters in column 72 of the BPECFG member. 9. Changed ISPF dialog to use the correct definition description when "S defname" used on the definition list command line to select a definition for editing.
Temporary fix
Comments
APAR Information
APAR number
PM32394
Reported component name
IMS CONNECT EXT
Reported component ID
5655K4800
Reported release
220
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2011-02-10
Closed date
2011-03-01
Last modified date
2011-08-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK65339
Modules/Macros
CEX##SEC CEX#MPAV CEX#MPIV CEX#MPSC CEX#OPSX CEX#TXTE CEXACLR1 CEXACL10 CEXBDDSG CEXBDSI0 CEXBDSI1 CEXBPSR CEXCERE CEXCMDT CEXCOMM CEXCONS CEXCONSC CEXCRPF CEXCR62 CEXCTPB CEXCVDB CEXDFDRV CEXEVTPR CEXEVT01 CEXEXRTR CEXLGDRV CEXMAIN CEXMPDEP CEXMPSCP CEXMSGCM CEXMSGL CEXMSGT CEXOPDRV CEXOPSVP CEXOPSV2 CEXOPSYP CEXOPSY1 CEXPRSR CEXPUDRV CEXR113 CEXR114 CEXR115 CEXR116 CEXR117 CEXR118 CEXR119 CEXR120 CEXR121 CEXR122 CEXR123 CEXR124 CEXR163 CEXSHELL CEXSVC01 CEXTECL CEXTRDEP CEXVUSER
Fix information
Fixed component name
IMS CONNECT EXT
Fixed component ID
5655K4800
Applicable component levels
R220 PSY UK65339
UP11/03/04 P F103
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX88S","label":"IMS Connect Extensions"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.2.0"}]
Document Information
Modified date:
22 October 2020