A fix is available
APAR status
Closed as program error.
Error description
While using Near Term History ( NTH ) SVCdump occurred: Log shows: KO2O1360E NEAR-TERM HISTORY DATA COLLECTOR - DATA CAPTURE FAILED WITH RC=10, RSC=030C, ARSC=000 DB2=T11D (CHKRETCD) CI0970: OMEGAMON SUBTASK ABEND CODE=840C1000 PSW=078C3000C88E9960 TCB=008995C8 CI0971: PROGRAM NAME=KO2PWTRF KO2S0500E OSNP SDUMPx Failure. RC: 00000208 Dump shows: ABEND0C4-10 KO2PCTOF+3DAA (at pm23887 level) on a BFFF1000 (ICM) instruction, R15 bad. And Abend0C1 KO2PCTOF + 494E ERROR DETECTED BY CO2PWTR S0C4 U0000 RC=00000010 PSW= 078C5000 C9539DEA AT CO2PCTO +003DAA PM23887 KO2S0508E OSNP LMOD: KO2SSRVB , CSECT: O2HPRC , OFFSET: 00CFE4 KO2PWTRF 0C4 ABEND0C4 ABENDS0C4
Local fix
Please apply ptf when available.
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component * * - OMEGAMON Collector * **************************************************************** * PROBLEM DESCRIPTION: ABEND0C4 PIC10 KO2PCTOF + 3DAA at * * PM23887 code level. * **************************************************************** * RECOMMENDATION: Apply this PTF * **************************************************************** ABEND0C4 in BLDXIX routine caused by uninitialized field use.
Problem conclusion
Code changed to fix this problem.
Temporary fix
Comments
APAR Information
APAR number
PM32013
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
510
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2011-02-04
Closed date
2011-05-16
Last modified date
2017-02-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK67740 UK67741 UK67742
Modules/Macros
KO2PCTOC KO2PCTOF
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R410 PSY UK67740
UP11/05/17 P F105
R420 PSY UK67741
UP11/05/17 P F105
R510 PSY UK67742
UP11/05/17 P F105
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.0"}]
Document Information
Modified date:
30 March 2021