A fix is available
APAR status
Closed as program error.
Error description
This APAR will address the following issues: - An 0C4 can occur in CEXRTPRT trying to format the results of a recorder trace conversion. - The IVP program sends IRM_F4 as x'00' when it should be a blank. This prevents HWSSMPL0/ or HWSSMPL1 from setting transactio expiration if requested in IRM_F1.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of IMS Connect Extensions V2.1 * **************************************************************** * PROBLEM DESCRIPTION: An 0C4 can occur in CEXRTPRT trying to * * format the results of a recorder trace * * conversion. * **************************************************************** * RECOMMENDATION: * **************************************************************** An 0C4 can occur in CEXRTPRT trying to format the results of a recorder trace conversion. The IVP program sends IRM_F4 as x'00' when it should be a blank. This prevents HWSSMPL0/1 from setting transaction expiration if requested in IRM_F1.
Problem conclusion
Code has been modified to correct this problem. After SMPE APPLY of this fix, Restart IMS Connect.
Temporary fix
Comments
APAR Information
APAR number
PM29379
Reported component name
IMS CONNECT EXT
Reported component ID
5655K4800
Reported release
210
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2010-12-21
Closed date
2011-03-01
Last modified date
2011-04-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK65338
Modules/Macros
CEXACLR1 CEXACL10 CEXRCDUT
Fix information
Fixed component name
IMS CONNECT EXT
Fixed component ID
5655K4800
Applicable component levels
R210 PSY UK65338
UP11/03/05 P F103
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.