APAR status
Closed as program error.
Error description
ABENDS0C4 FABAINIT x'18be' running FABADA1. When DEDBPC sets segment information in the getmained table, it puts information into the preceding 8 bytes of the getmained buffer. The abend is caused by the preceding 8 bytes of the getmained buffer being freemained prior to the setting of the information. This abend is possible when DEDBPC runs with SDEP=YES and SPTFALL=YES against the area that contains the SDEP segment.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All DEDB Pointer Checker users of HPFPU FP * * Basic Tools Version 3 Release 2 who define * * SDEP segment type in DBD definition * * (FMID: H31A320). * **************************************************************** * PROBLEM DESCRIPTION: FPB DEDB Pointer Checker (DEDBPC) gets * * S0C4 abend when runs a area defined * * SDEP segment type. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** DEDBPC puts SDEP segment information into the preceding 8 bytes of the getmained buffer in error when SDEP segment type is defined in DBD definition. The abend S0C4 is caused when the preceding 8 bytes of the getmained buffer is unusable such as being freemained. This abend is possible when DEDBPC runs a area defined SDEP segment type in DBD definition despite the sysin keywords of DEDBPC.
Problem conclusion
DEDBPC is modified to put the SDEP segment information into the getmained buffer. 320Y FABAINIT
Temporary fix
Comments
APAR Information
APAR number
PM26948
Reported component name
IMS HP FP UTILI
Reported component ID
5655K9400
Reported release
320
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2010-11-17
Closed date
2010-11-28
Last modified date
2010-12-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
PM26992 UK62593
Modules/Macros
FABAINIT
Fix information
Fixed component name
IMS HP FP UTILI
Fixed component ID
5655K9400
Applicable component levels
R320 PSY UK62593
UP10/11/30 P F011