IBM Support

PM24906: ERRORS ENCOUNTERED DURING MONITOR EOF PROCESSING ARE NOT REPLICATED IN THE SYSPRINT OUTPUT

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Errors encountered during Monitor reporting are reported via
    the diags output (IPIDIAGS) and are summarized at EOF in
    SYSPRINT.  Any errors encountered during EOF are reported only
    in the diags output and not in SYSPRINT.
    
    Two additional issues addressed:
    1) Transaction Stop time of zero (no transaction stop time)
       triggers an internal error.
    2) Fast Path utilities should be treated as BMPs for Monitor
       PROGSUM report (not as transactions).
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IMS Performance Analyzer V4.2       *
    ****************************************************************
    * PROBLEM DESCRIPTION: 1.Errors encountered during Monitor EOF *
    *                      processing are not replicated in the    *
    *                      SYSPRINT output.                        *
    *                      2.Transaction Stop time of zero         *
    *                      triggers an internal error.             *
    *                      3.Fast Path utilities should be treated *
    *                      as BMPs for Monitor PROGSUM report.     *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    1. Errors encountered during Monitor reporting are reported via
    the diags output (IPIDIAGS) and are summarised at EOF in
    SYSPRINT. Any errors encountered during EOF are reported only in
    the diags output and not in SYSPRINT.
    2. No Transaction Stop time is treated as an internal error.
    3.Fast path utilities are treated as transactions.
    

Problem conclusion

  • 1. Any errors encountered in Monitor EOF should be reported in
    SYSPRINT not in diags.
    Add informational message IPI0098I to indicate if the
    Monitor input may have been truncated (i.e. no logical
    EOF record found).
    NOTE: this message will not be produced if a time range
    is specified for the Monitor report.
    2. If no Stop time for a transaction use the Start time.
    3. Treat Fast Path utilities as BMPs for Monitor reporting.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM24906

  • Reported component name

    IMS PERF ANALYZ

  • Reported component ID

    5655E1500

  • Reported release

    420

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2010-10-20

  • Closed date

    2010-11-02

  • Last modified date

    2010-12-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK61862

Modules/Macros

  •    IPIAMSCN IPIAQR11 IPIARSUM IPIMSGS  IPIMSGT
    IPISAPAR
    

Fix information

  • Fixed component name

    IMS PERF ANALYZ

  • Fixed component ID

    5655E1500

Applicable component levels

  • R420 PSY UK61862

       UP10/11/05 P F011

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8A2","label":"IMS Performance Analyzer"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"420"}]

Document Information

Modified date: