IBM Support

PM24860: CEX 220 PROVIDE RUNUNDER SUPPORT FOR IMS V12

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as new function.

Error description

  • Provide rununder support for IMS V12.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IMS Connect Extentions V2.2         *
    ****************************************************************
    * PROBLEM DESCRIPTION: Provide rununder support for IMS V12.   *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    This APAR is making changes for the following issues:
    Provide rununder support for IMS V12.
    1. IMS V12 added new event records, IMS Connect type 1 commands,
    an IMS Connect configuration member keywords
    2. An abend 0C4 can occur when the CEX trace is active and the
    amount of data to trace is 1 byte shorter than the CEX trace
    buffer. The abend occurs in module CEXTECL
    3. Provide support for IMS Connect APAR PM04698.
    4. CEX Security checking is not performed for HWSJAVA0 client
    if event recording is not active.
    5. Event record decimal 61 flag CERE_61_CX1_FLAG1 is incorrect
    when the message exit call function is EXER
    

Problem conclusion

Temporary fix

Comments

  • The following changes have been made for the above issues:
    1. Provide toleration support to the new events, type 1 commands
    and configuration keyword changes
    2. Changed the CEX trace code in module CEXTECL to detect that
    there is less than 2 bytes of trace buffer left and handle the
    situation accordingly.
    3. When IMS Connect APAR PM04698 is installed, CEX now creates a
    CE trace event record showing the SCI data sent and received in
    IMS Connect from the IMS SCI environment.
    4. If event recording was not active, the CEX security process
    did not properly detect an HWSJAVA0 client and so security
    checking was not performed when event collection was not active.
    5. Message exit parmlist field EXPEXR_FLAG1 is at a different
    offset when the exit call function is for EXER. Corrected
    CEXTECL to use the correct offset for EXPEXR_FLAG1 when building
    the CERE_61_CX1_FLAG1.
    

APAR Information

  • APAR number

    PM24860

  • Reported component name

    IMS CONNECT EXT

  • Reported component ID

    5655K4800

  • Reported release

    220

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    YesSpecatt / New Function / Xsystem

  • Submitted date

    2010-10-19

  • Closed date

    2011-05-23

  • Last modified date

    2011-06-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK68052

Modules/Macros

  • CEX#ABCH CEX#EXAC CEX#EXAO CEX#EXDT CEX#EXEX
    CEX#EXGO CEX#EXLL CEX#EXM1 CEX#EXM2 CEX#EXOF CEX#EXPO CEX#EXUO
    CEX#EXX1 CEX#EXX2 CEX#EXX3 CEX#SHCS CEX#SHEL CEX#TXUP CEXACL10
    CEXBCMD0 CEXBDSI1 CEXBDST0 CEXCDSB  CEXCERE  CEXCOLLV CEXCONS
    CEXCONSC CEXCONSS CEXCR56  CEXCR57  CEXCR61  CEXCR62  CEXCVDB
    CEXDFDRV CEXD01   CEXEDDEP CEXEVTPR CEXEVT01 CEXEXRTR CEXE07
    CEXMAIN  CEXRSNT  CEXR113  CEXR114  CEXR115  CEXR116  CEXR117
    CEXR118  CEXR119  CEXR120  CEXR121  CEXR122  CEXR123  CEXR124
    CEXR125  CEXR126  CEXR164  CEXTECL  CEXTRSMP
    

Fix information

  • Fixed component name

    IMS CONNECT EXT

  • Fixed component ID

    5655K4800

Applicable component levels

  • R220 PSY UK68052

       UP11/05/26 P F105

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX88S","label":"IMS Connect Extensions"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.2.0"}]

Document Information

Modified date: