A fix is available
APAR status
Closed as program error.
Error description
Occurrence of the messages FPEV0266I ... EXCEPTION PROCESSING DIAGNOSTIC DATA: DB2 TIMEOUT FPEV0267I ... EXCEPTION PROCESSING DIAGNOSTIC DATA: RA PRESERVED FOR LATER USE followed by the messages FPEV0560E ... DB2 RETURNED INCORRECT DATA. REQUEST CANCELED IEA794I SVC DUMP HAS CAPTURED: ... DUMP TITLE=INCORRECT RA - DB2I and/or ABEND S0C1 in FPEMEXA0, ABEND S0C4 in FPEVDB2I, DGOVTCPL or unknown module, or other types of ABENDs in various modules.
Local fix
n/a
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component * * - OMEGAMON collector * * - PE Server subtask * * - Classic Interface * * - ISPF Monitoring dialogs * * - Performance Expert Client * * - Performance Expert Agent for * * DB2 Connect Monitoring * **************************************************************** * PROBLEM DESCRIPTION: Occurrence of timeouts which last * * longer than 60 seconds in a DB2 * * subsystem being monitored by PE * * Server subtask causes inoperability * * of all kind of clients interacting with * * this PE Server subtask, A while later * * OMEGAMON Collector started task * * terminates due to abend S0C1 or S0C4. * **************************************************************** * RECOMMENDATION: Apply this PTF. * * * * When the messages FPEV0266I and FPEV0267I * * come up in JES outputs of a corresponding * * OMEGAMON Collector started task, take prompt * * actions to locate and prevent occurrence of * * timeouts in corresponding DB2 subsystems. * * Neglecting of this requirement may cause * * the PE Server subtasks to terminate. * **************************************************************** PROBLEM SUMMARY: Occurrence of the messages FPEV0266I ... EXCEPTION PROCESSING DIAGNOSTIC DATA: DB2 TIMEOUT FPEV0267I ... EXCEPTION PROCESSING DIAGNOSTIC DATA: RA PRESERVED FOR LATER USE followed by the messages FPEV0560E ... DB2 RETURNED INCORRECT DATA. REQUEST CANCELED IEA794I SVC DUMP HAS CAPTURED: ... DUMP TITLE=INCORRECT RA-DB2I and/or ABEND S0C1 in FPEMEXA0, ABEND S0C4 in FPEVDB2I, DGOVTCPL or in unknown module, or other types of ABENDs in various modules. A corresponding instance of PE Server subtask monitoring the DB2 subsystem given is stopped. PROBLEM CONCLUSION: The code of PE Server subtask has been modified to solve this problem. KEYWORDS: FPEV0266I FPEV0267I S0C1 S0C4 INCORRECT-RA-DB2I
Problem conclusion
PROBLEM CONCLUSION: The code of PE Server subtask has been modified to solve this problem. KEYWORDS: FPEV0266I FPEV0267I S0C1 S0C4 INCORRECT-RA-DB2I
Temporary fix
Comments
APAR Information
APAR number
PM21347
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
420
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2010-08-26
Closed date
2010-10-26
Last modified date
2011-06-22
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK61652
Modules/Macros
DGOVABAN DGOVMSTR FPE@DB2I FPE@DB2S FPE@WRP2 FPEMEXA0 FPEVDB2I FPEVDB2S FPEVTMEM FPEVWRP2
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R420 PSY UK61652
UP10/10/30 P F010
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"420"}]
Document Information
Modified date: