IBM Support

PM20699: ABEND878-14 RUNNING ANALYZE ON LARGE AREA

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • ABEND878 RC14 running ANALYZE upon a very large Area.
    The ABENDS878 is caused by R9 having a negative value on the
    GETMAIN being attempted. It seems to fail after the ANALYZE for
    the area is complete, however no report comes out.
    Another symptom is an HPFP ABEND3006.
    
    Additional issue addressed: ABEND0C7 in HFPA5T20
    processing large AREA with ANALYZE command.
    
    Keywords: S878 S0C7 ABENDS0C7
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of High Performance Fast Path      *
    *                 Utilities Fast Path Advanced Tool Version 3  *
    *                 Release 2 (FMID: H31A320).                   *
    ****************************************************************
    * PROBLEM DESCRIPTION: 1.ABENDS878 RC14 running HFPA5XT0 due   *
    *                        to a huge DEDB record in the user     *
    *                        DEDB area. HFPA5XT0 could not handle  *
    *                        such a large record, therefore the    *
    *                        routine will be adjusted to handle    *
    *                        larger records.                       *
    *                      2.ABENDS0C7 occurred when the total     *
    *                        number of "IOVF used CI" was          *
    *                        6 digits.                             *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    1.FPA ANALYZE stacks CI RBA information in the internal table.
      When all entries of the table consumed, then the table will be
      expanded by GETMAINing extended table.
      The GETMAIN failed with S878 system code due to the negative
      value of storage size to be obtained.
    2.FPA ANALYZE(HFPA5T20) got the system exception when it
      calculates the standard deviation of the total number of IOVF
      used CI.
      This abend0C7 occurs when the total number of "IOVF used CI"
      and the total number of "DOVF used CI" are greater than
      100000.
    

Problem conclusion

  • 1.The internal table will be extended every time when all
      entries of the table consumed.
      The total number of entries is saved in the half word field so
      that the number can be up to 32,767 represented by half word
      signed binary.
      When the increased number is greater than 32,767, then half
      word overflow condition happens and the obtained value form
      the half word field come to be negative value.
      Thus GETMAIN failure with S878 happened.
    
      HFPA5XT0 has been modified from LH/STH to L/ST to load/store
      from/to full word field.
    
    2.HFPA5T20 did not prepare the field to square the total number
      of "IOVF used CI"(PL5). It is modified to use the field
      defined with PL10 to square.
    320Y
    HFPA5T20
    HFPA5WKG
    HFPA5WK2
    HFPA5W00
    HFPA5XT0
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM20699

  • Reported component name

    IMS HP FP UTILI

  • Reported component ID

    5655K9400

  • Reported release

    320

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2010-08-17

  • Closed date

    2010-08-26

  • Last modified date

    2011-07-25

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK59993 PM44385

Modules/Macros

  •    HFPA5T20 HFPA5WKG HFPA5WK2 HFPA5W00 HFPA5XT0
    

Fix information

  • Fixed component name

    IMS HP FP UTILI

  • Fixed component ID

    5655K9400

Applicable component levels

  • R320 PSY UK59993

       UP10/08/27 P F008