Error description
Abend 0C4 in program CIUA160C seen intermittently running transaction CINT.
Local fix
fix available by PTF
Problem summary
**************************************************************** * USERS AFFECTED: All CICS IA Version 3.2 users. * **************************************************************** * PROBLEM DESCRIPTION: Value of "Total time PAUSED" * * calculated in module CIUA160C * * is negative. The FORMATTIME command * * fails with INVREQ and one of the * * following decimal commands fails * * with 0C7. * **************************************************************** * RECOMMENDATION: Apply the PTF and perform HOLD action. * **************************************************************** It is HOURGLASS causing the problem. When the customer uses it they do not change the date from day to day just the time. So when CICS IA does a START/STOP over midnight it work calculates the total time started , paused etc. we can calculate negative values and we try and format them and we go splat.
Problem conclusion
Code has been added to corect negative time interval to positive ( 0 hr. <= Time Interval < 24 hr.) and to issue message 2400 if negative time interval occurs.
Temporary fix
Comments
APAR Information
APAR number
PM74057
Reported component name
CICS INTER ANAL
Reported component ID
5655U8600
Reported release
320
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-10-01
Closed date
2013-01-31
Last modified date
2013-04-11
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK91325 UK91326 UK91327 PM86828
Modules/Macros
CIUA120C CIUA130C CIUA140C CIUA160C CIUA180C CIUCINBE CIUCINB1 CIUCINB2 CIUCINTE CIUMSGE CIUMSGK
Fix information
Fixed component name
CICS INTER ANAL
Fixed component ID
5655U8600
Applicable component levels
R32E PSY UK91326
UP13/02/08 P F302
R32K PSY UK91327
UP13/02/08 P F302
R320 PSY UK91325
UP13/02/08 P F302
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSPPUS","label":"CICS Interdependency Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]