Error description

  • DB2 Object Comparison Tool for z/OS fails to ALTER TRIGGERs with
    proper timestamp sequence to ensure proper execution sequence
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of the DB2 Object Comparison Tool      *
    *                 for z/OS who compare DB2 triggers that       *
    *                 have the same triggering SQL operation       *
    *                 and activation time.                         *
    ****************************************************************
    * PROBLEM DESCRIPTION: A DROP/CREATE of a DB2 trigger that     *
    *                      has the same triggering SQL operation   *
    *                      and activation time as other triggers   *
    *                      will be invoked out of order if it      *
    *                      was not originally invoked last.        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    A DROP/CREATE of a DB2 trigger that has the same triggering SQL
    operation and activation time as other triggers can fail
    because it is invoked out of order.
    

Problem conclusion

  • The DB2 Object Comparison Tool has been corrected to maintain
    the invocation order of DB2 triggers that have the same
    triggering SQL operation and activation time.  Note that if a
    new trigger is being added to an existing set of triggers
    with the same triggering SQL operation and activation time,
    at least one of the existing triggers is needed in the source
    to establish a position for the new trigger. If the new
    trigger needs to be positioned last, no existing trigger is
    required.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM67504

  • Reported component name

    DB2 OBJECT COMP

  • Reported component ID

    5697G6400

  • Reported release

    A10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-06-22

  • Closed date

    2012-08-21

  • Last modified date

    2012-09-25

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  •    ADBCDTS  ADB2CMF  ADB2CMP  ADB2CMR  ADB2CMS
    ADB2CMT
    

Fix information

  • Fixed component name

    DB2 ADMIN TOOL

  • Fixed component ID

    568851500

Applicable component levels

  • RA10 PSY UK81227

       UP12/08/24 P F208

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSCVQTD","label":"IBM Db2 Administration Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]