IBM Support

PM64743: INTEGRITY CHECKER ENHANCEMENT FOR SUPPRESSING MESSAGE WHEN NO GLOBAL OPTION MODULE IS EXIST IN THE STEPLIB

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as new function.

Error description

  • This APAR changes Integrity Checker not to issue any message
    when no global option module is exist in the STEPLIB.
    And, this APAR also changes Integrity Checker message to show
    IMS version.
    This APAR addresses FITS REQ MR0409121339 and MR0522126949.
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: IMS Library Integrity Utilities for z/OS,    *
    *                 Version 2 Release 1 (FMID=H27P210) users.    *
    ****************************************************************
    * PROBLEM DESCRIPTION: This APAR changes the behavior of       *
    *                      Integrity Checker to address FITS       *
    *                      requirements MR0409121339 and           *
    *                      MR0522126949.                           *
    *                      1. Suppresses Integrity Checker WTO     *
    *                      messages if a global option module is   *
    *                      not set up.                             *
    *                      2. Displays the version of IMS in an    *
    *                      Integrity Checker message.              *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    By this APAR, the following two changes are made to the
    Integrity Checker utility:
    
    1. Suppresses Integrity Checker WTO messages if a global option
    module is not set up.
    
    To activate Integrity Checker, a global option module must be
    created and added to the STEPLIB concatenation. In other words,
    if a global option module is not found in the STEPLIB
    concatenation, Integrity Checker will not be activated.
    
    Integrity Checker issues the following messages when a global
    option module is not found:
      FABL0103W LIU INTEGRITY CHECKER DEACTIVATED
      FABL0113W LIU CONFIGURATION NOT FOUND
      FABL0114I IMS VERSION WAS RETRIEVED
    These messages can mislead users by implying unexpected warning
    conditions.
    
    This APAR suppresses these messages when a global option module
    is not found in the STEPLIB concatenation. Specific changes are
    as follows:
     - Messages FABL0103W and FABL0113W are deleted.
     - Message FABL0114I is issued only when a global option module
    is found.
    
    2. Displays the version of IMS in an Integrity Checker message.
    
    This APAR changes the FABL0114I message as follows:
      FABL0114I LIU INTEGRITY CHECKER ACTIVATED. IMS VERSION IS
    version
    
    As previously described, this message is issued only when
    Integrity Checker is activated. The new message text clearly
    describes the processing status together with the version of IMS
    that is being used.
    

Problem conclusion

Temporary fix

Comments

  • The following modules and macros have been modified.
    
    FABLAH1 , FABLAH1A, FABLAH1B, FABLAH1C, FABLAH19, FABLAI0 ,
    FABLICI0, FABLIMSM, FABLTC00, FABLWMT
    
    ========================
    = DOCUMENTATION CHANGE =
    ========================
    Changes will be made to the IMS Library Integrity Utilities for
    z/OS User's Guide (SC19-2479-01). For details, see documentation
    updates in the IMS Tools Product page:
    http://www-01.ibm.com/support/docview.wss?uid=swg27020942
    

APAR Information

  • APAR number

    PM64743

  • Reported component name

    IMS LIBR INTEG

  • Reported component ID

    5655I4200

  • Reported release

    210

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2012-05-15

  • Closed date

    2012-09-06

  • Last modified date

    2012-10-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK81553

Modules/Macros

  • FABLAH1A FABLAH1B FABLAH1C FABLAH19 FABLAI0
    FABLICI0 FABLIMSM FABLTC00 FABLWMT
    

Publications Referenced
SC19247901    

Fix information

  • Fixed component name

    IMS LIBR INTEG

  • Fixed component ID

    5655I4200

Applicable component levels

  • R210 PSY UK81553

       UP12/09/13 P F209

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89N","label":"IMS Library Integrity Utilities"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: