IBM Support

PM64619: PROVIDE NEW SESSION MESSAGE LIMIT FEATURE

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as new function.

Error description

  • New Session Message Limit feature to allow automatic persistent
    session rebalancing when a persistent session has reached a user
    specified number of sent messages.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IMS Connect Extentions V2.3         *
    ****************************************************************
    * PROBLEM DESCRIPTION: Provide new Session Message Limit       *
    *                      feature                                 *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    This APAR is addressing the following:
    1. New Session Message Limit feature to allow automatic
    persistent session re-balancing when a persistent session
    has reached a user specified number of messages.
    2. The CEX IVP does not support messages exit HWSSMPL0.
    3. If OTMA degraded performance for Global Warning is active,
    IMS only sets a degraded status of Global Warn.
    CEX Routing will continue to send messages to a
    datastore in Global Warn status if that is the only choice
    available. Currently, IMS does not set Global Fail so it
    is possible to abend IMS.
    4. CEX Rules Based Routing does not provide an option to have
    CEX send an RSM to the client when there are no available
    datastore candidates available.
    Transaction routing supplies and option to return the
    message to IMS Connect with the original datastore or
    to reject the message with an RSM. If the client is using
    a Generic datastore name and it is returned to IMS Connect,
    Message HWSS0742W is issued because the generic datastore
    name is not known to IMS Connect.
    5. Refresh command issues messages, CEX2021, CEX2022, and
    CEX22023 even if the command ends with RC=4
    

Problem conclusion

Temporary fix

Comments

  • The following changes have been made for the above issues:
    1. With this new feature active and the SYSPLEX distributor
    being used, when a persistent session has reached a
    user specified number of sent messages, IMS Connect
    Extensions will close the session. When a new persistent
    is subsequently requested, the SYSPLEX distributor will
    rebalance the sessions.
    2. Add 4 new test cases to the IVP that are the same as test
    cases 1 - 4 but that use exit HWSSMPL0.
    3. A new Option is added to the CEXROUTE command that allows
    the ability to treat the Global Warn condition as if it
    was a Global Fail condition. If this option is chosen,
    CEX Routing will not route to a datatore that is in
    Global Warn status.
    4. A new option of the CEXROUTE command is provided that
    provides the ability to have CEX return an RSM to the
    client and prevent the HWSS0742W message.
    5. Corrected Refresh command to not issue messages when
    the command fails due to RC=4
    

APAR Information

  • APAR number

    PM64619

  • Reported component name

    IMS CONNECT EXT

  • Reported component ID

    5655K4800

  • Reported release

    230

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    YesSpecatt / New Function / Xsystem

  • Submitted date

    2012-05-14

  • Closed date

    2012-07-23

  • Last modified date

    2012-08-09

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK80469

Modules/Macros

  • CEX#MPDT CEX#MPSM CEX#SHCS CEX#SHEL CEXACL10
    CEXBDDSG CEXBDSI1 CEXCONS  CEXCONSS CEXCPSR  CEXCR62  CEXCSE06
    CEXCSE07 CEXCSE08 CEXCSE09 CEXCSKT  CEXDFDRV CEXEFW   CEXEPR
    CEXEVTPR CEXEVT01 CEXEVWTR CEXEXRTR CEXE05   CEXGUIW  CEXIVP6
    CEXIVP7  CEXIVP8  CEXIVP9  CEXJRNEX CEXMAIN  CEXMPDEP CEXMSGCM
    CEXMSGL  CEXMSGT  CEXOPDRV CEXPRED0 CEXPRED1 CEXPUBMN CEXPUDRV
    CEXRCDPR CEXRCDUT CEXREAD  CEXROUT0 CEXR168  CEXSALUT CEXSVC01
    CEXTECL  CEXTECL1 CEXTEOT  CEXTPXML H28S230J
    

Fix information

  • Fixed component name

    IMS CONNECT EXT

  • Fixed component ID

    5655K4800

Applicable component levels

  • R230 PSY UK80469

       UP12/08/01 P F207

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX88S","label":"IMS Connect Extensions"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.3.0"}]

Document Information

Modified date:
22 October 2020