IBM Support

PM61269: CONVERTING SYSTCPDA TO SNIFFER OR TCPDUMP LEADS TO INCORRECT LENGTH VALUES IN THE RESULTING CAP OR PCAP FILES

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • IPCS command ctrace comp(systcpda) with these options
    options((sniffer(1500))) or
       options((sniffer(1500 tcpdump)))
    is used to convert a SYSTCPDA packet trace to a format
    compatible with WireShark or TCPDUMP analysis tools,
    respectively.
    After conversion,  the number of 'bytes on wire' is higher than
    the 'bytes captured' even when the trace was not abbreviated
    during capture.
    Wireshark reports:
    [Packet size limited during capture: PRP truncated]
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of the IBM Communications Server   *
    *                 for z/OS Version 1 Release(s) 13: IP         *
    *                 Packet Trace Formatter                       *
    ****************************************************************
    * PROBLEM DESCRIPTION: Sniffer files created by the packet     *
    *                      trace formatter were reporting frame    *
    *                      lengths that were longer than the       *
    *                      actual frame length.                    *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    The frame length and the capture data length were incorrectly
    calculated.
    +-------------------------------------------------------------+
    + Please check our Communications Server for OS/390 homepages +
    + for common networking tips and fixes.  The URL for these    +
    + homepages can be found in Informational APAR II11334.       +
    +-------------------------------------------------------------+
    

Problem conclusion

  • EZBPTSNF has been amended to correctly calculate the frame
    length and captured length and place these values into the
    sniffer trace records.
    
    * Cross Reference between External and Internal Names
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM61269

  • Reported component name

    TCP/IP V3 MVS

  • Reported component ID

    5655HAL00

  • Reported release

    1D0

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-03-27

  • Closed date

    2012-04-09

  • Last modified date

    2012-05-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UK77768

Modules/Macros

  • EZBPTSNF
    

Fix information

  • Fixed component name

    TCP/IP V3 MVS

  • Fixed component ID

    5655HAL00

Applicable component levels

  • R1D0 PSY UK77768

       UP12/04/25 P F204

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1D0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSCY4DZ","label":"DO NOT USE"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1D0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: