  • Closed as program error.

Error description

  • The Client daemon process (cclclnt) uses 100% of the processor
    when no requests are being made. This can affect actions,
    such as CICS TG attempting to reconnect to servers that are
    unavailable. When a request is made, such as an ECI request or
    status request using cicscli/l, the 100% processor usage ends
    and the request is processed correctly.
    

Local fix

  • Run the 'cicscli -l' command to end the 100% processor usage.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of CICS Transaction Gateway on     *
    *                 UNIX or Linux platforms.                     *
    ****************************************************************
    * PROBLEM DESCRIPTION: The Client daemon uses 100% of the      *
    *                      processor when no requests are being    *
    *                      made                                    *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    CICS TG uses messages internally to trigger actions at specific
    times. Under certain timing conditions an internal flag is not
    reset correctly when processing these messages. This incorrect
    flag value causes the Client daemon to loop until another
    message is processed.
    

Problem conclusion

  • CICS Transaction Gateway has been changed so that flag is reset
    correctly. This prevents the loop from occurring, therefore
    resolving the problem.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM55800

  • Reported component name

    CICS TRNS GATE

  • Reported component ID

    5724I8102

  • Reported release

    800

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2012-01-11

  • Closed date

    2012-03-09

  • Last modified date

    2016-09-12

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • CTGV8DUM
    

Fix information

  • Fixed component name

    CICS TRNS GATE

  • Fixed component ID

    5724I8102

Applicable component levels

  • R800 PSY

       UP

  • R810 PSY

       UP

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMJ2","label":"CICS Transaction Gateway"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.0","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
06 January 2022