A fix is available
APAR status
Closed as program error.
Error description
When running a TWSz controller task (any release) under z/OS 1.13 or higher, and using the OPCOPTS parameter RECOVERY(YES), an abendS66D ( 66D - 31 ) is seen in the controller. Checking the dump, the abend is at IGX00027+150 on a call to TSO STACK service. Abend S66D-31 means a TSO/E service that requires a TSO/E environment was invoked in a non-TSO/E environment. . Program EQQZMSGT + x'266', invokes the CALLTSSR macro to call the STACK service, which causes an immediate failure in IGX00027+x'150' - where an ABEND66D-31 is issued because this is not a TSO environment. . The same code worked correctly in z/OS 1.12 and lower. The abend can be taken even with RECOVERY(NO) coded . KEYWORDS FOR FIXCAT and SEARCHABILITY: RELEASE13 RELEASE113 ZOSR13 ZOSR113 ZOS113T/K ZOS13 ZOSV1R13 Z/OSV1R13 R13 ZOS113 ZOS0201T/K ZOS0202T/K
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All TWS for z/OS users. * **************************************************************** * PROBLEM DESCRIPTION: A system abend 66D with RC=31 can * * occur at start time of a TWSz started * * task. * **************************************************************** * RECOMMENDATION: APPLY THE PTF FIXING THIS APAR * **************************************************************** A system abend 66D with RC=31 can occur at start time of a TWSz started task on a z/OS 1.13 system.
Problem conclusion
The problem occurs because the TSO checks the LWALWA field that should contain the value ' LWA '; since the TWSz builds its own LWA area, this field was not filled in with the above value. 300Y 500Y 510Y 600Y EQQZTSOX
Temporary fix
Comments
APAR Information
APAR number
PM54802
Reported component name
TIV WRKLD SCHD
Reported component ID
5697WSZ01
Reported release
600
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2011-12-21
Closed date
2012-01-13
Last modified date
2016-05-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UK75421 UK75422 UK75423 UK75424
Modules/Macros
EQQZTSOX
Fix information
Fixed component name
TIV WRKLD SCHD
Fixed component ID
5697WSZ01
Applicable component levels
R300 PSY UK75421
UP12/03/08 P F203
R500 PSY UK75422
UP12/03/08 P F203
R510 PSY UK75423
UP12/03/08 P F203
R600 PSY UK75424
UP12/03/08 P F203
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSRULV","label":"IBM Workload Scheduler for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"600","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"600","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
06 May 2016